Télécharger Imprimer la page

Roco and Fleischmann WLANmaus Z21 Mode D'emploi page 82

Masquer les pouces Voir aussi pour WLANmaus Z21:

Publicité

Les langues disponibles

Les langues disponibles

3.8
"TURN-OFF TIME"
To save battery power of the WLANmaus, the unut switches off automatically after a defined period
of time when not being used.
Value range: 1–255, factory setting: 10 minutes
Select with the arrow keys and confirm input with the OK-key.
You are returned to "TURN-OFFTIME."
3.9
"CONTROL UNIT"
Depending on the connected control unit, a dynamic menu for various control unit settings is gener-
ated here. "Dynamic" in this case means that, depending on the identified control unit, submenus are
only generated for the available settings.
Note: If the control unit is not recognised or is a product from a third-party manufacturer, the scroll-
ing text "UNKNOWN" appears when you access this submenu
3.9.1 "RAILCOM"
This option lets you specify whether all RailCom-specific functions (automatic generation of
a RailCom cut-out after each DCC command and evaluation of RailCom feedback) should be
enabled or disabled.
Options: "ON" or "OFF."
To select an option, use the arrow keys.
Confirm with the OK-key. You will then be returned to the initial "RAILCOM" level.
3.9.2 "STOP BUTTON"This option is used to set the function of the STOP button on the control centre.
Options: "VOLTAGE OFF" or "EMERGENCY STOP".
To select an option, use the arrow keys.
Confirm with the OK-key. You will then be returned to the initial "STOP BUTTON" level.
Note: If the connected control unit is a smartRail, this menu item does not appear.
3.9.3 "CV READING MODE"
With this option you can set the way CVs should be read out from a decoder. It should be noted
that when reading out individual bits, only a few accesses are necessary, whereas when reading
out whole bytes, many accesses are often necessary until the correct value is found, which in
the worst case may require 256 attempts and therefore take a very long time.
Options: "DO NOT READ", "BIT BY BIT", "BYTE BY BYTE" or "BIT BY BIT AND BYTE BY BYTE".
To select an option, use the arrow keys.
Confirm with the OK-key. You will then be returned to the initial "CV READ MODE" level.
3.9.4 "TRACK VOLTAGE"
You can then set the track voltage for the main track. Please note that the output track voltage
cannot be higher than the voltage from the power supply being used.
Value range: 12.0 – 24.0 V, resolution: 0.5 V
For example: "18.5V".
82
82
8010813920_II_2022.indd 82
8010813920_II_2022.indd 82
"VOLTAGE OFF": The track voltage is switched off.
"EMERGENCY STOP": If the track voltage is maintained,
an emergency stop command is sent to all locos.
"DO NOT READ": no read-out processes take place.
"BIT BY BIT": individual bits are read out from the decoder.
"BYTE BY BYTE": individual bytes are read out from the decoder.
"BIT BY BIT AND BYTE BY BYTE": First, an attempt is made to read out the decoder
bit by bit. If this does not succeed, it is read out byte by byte.
09.02.2022 09:17:30
09.02.2022 09:17:30

Publicité

loading

Produits Connexes pour Roco and Fleischmann WLANmaus Z21