Max.strokelimitation
7.2 Actuator sizes 100, 125 (Ø in mm)
e.g. Loctite 274
Image 4: Actuator sizes 100, 125 (Ø in mm),
max. stroke limitation without position feedback
7.2.1 Work before installation
Interrupt the supply of pilot air and medium flow.
Drain the valve body.
Unscrew the transparent cap from the actuator cover (6)
(observe the safety instructions in chapter "7" on page 10!).
Unscrew the position indicator with an Allen key (AF8).
NOTE!
Damage caused by wrong tool.
▶ Only screw the actuator cover in or out with the special wrench
offered in chapter "12 Installation accessories".
Unscrew the actuator cover (6) with a special wrench while
holding on to the running surface.
Required parts
1 Threaded nipple
2 Setscrew M12 x 1.5
3 Nut M12 x 1.5
4 Nut
5 O-ring
6 Actuator cover
7 Bush
8 Washer
7.2.2 Installation and commissioning
NOTE!
Failure or impairment of function due to damaged O-ring (5).
• Insert O-ring (5) carefully.
• Do not use any sharp objects to insert.
Insert the threaded nipple (1) into the actuator cover (6).
Insert the washer (8) into the inside of the actuator cover (6).
Fasten actuator cover (6) with nut (4) on threaded nipple (1).
• Use wrench flat on the tube (AF24)
• Max. tightening torque: 20 Nm
Secure nut (4) with adhesive (e.g. Loctite 274).
Mount the actuator cover (6) with a special wrench.
• Max. tightening torque:
Adjust the max. stroke by adjusting the setscrew (2).
Secure setscrew (2) with nut (3).
Check valve for functionality and tightness.
English
Actuator size Ø 100 mm = 45 Nm
Actuator size Ø 125 mm = 60 Nm
11