Cleaning And Care; Overheating Protection Circuit - Unold Fan+Heat 86106 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
For heating operation select the
desired temperature via the rotary
thermostat regulator, by turning
the regulator. The regulator is
variably adjustable. The indicator
light shows the mode.
5.
The appliance heats until the
desired temperature is reached,
then the appliance switches off.
The appliance will switch on again
as soon as the room temperature
drops below the set temperature.
Fan operation
Level "
" for the fan function
(cool air)
Attention: If the appliance was
previously on heating operation,

CLEANING AND CARE

Switch off the appliance. To
switch off the appliance, place
the rotary regulator on position
"O" and unplug the mains plug.
Allow the appliance to cool
completely.
1.
Never use any abrasive scouring
agents, steel wool, metal objects,
hot cleaning agents or disinfec-
tants.

OVERHEATING PROTECTION CIRCUIT

1.
The appliance is equipped with
an overheating protection circuit
that switches the appliance off
when it is heated over 70° C.
2.
If the overheating protection cir-
cuit has been tripped, switch the
appliance off, unplug the plug
from the electrical outlet and let
22
Copyright UNOLD AG | www.unold.de
the outflowing air will still be
warm initially. Depending on the
previous heating capacity it can
take some time until the appli-
ance provides cool air.
When you adjust the fan function,
you must place the rotary ther-
mostat regulator on the highest
position.
6.
To switch off the appliance, place
the rotary regulator on position
"O" and unplug the mains plug.
Be aware that the appliance
can become very hot - fire ha-
zard! Particularly ensure that
children are kept away from
the appliance.
2.
You can remove dust in the
appliance if you carefully hold a
vacuum cleaner against the air
inlet and outlet grille.
3.
Store the fan heater in a dry, safe
place so that it is protected from
dust, shocks, heat and moisture.
the appliance cool for at least
30 minutes.
3.
Eliminate the cause of the over-
heating, (e.g. excessive dust in
the appliance, air outlet grille is
covered) and start up the appli-
ance again.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

86106

Table des Matières