person, you can save it and compare it to the temperature when you are
measuring for fever.
4.2. BODY TEMPERATURE REGULATION
When the body temperature rises or falls, the body initially regulates its
temperature from the brain. Since the temple and the ear are the body
parts nearest the brain, they are the first to be informed of a temperature
rise.
4.3. HOW TO PROPERLY USE THE THERMOMETER IN
TEMPORAL MODE
SEE DIAGRAM
A
PAGE 3.
Easyscan™ VM-ZX1 is pre-configured at the factory. It is not necessary to
calibrate the device when it is first used.
Keep the tip containing the temporal probe on the unit.
Place the thermometer against the right temple, where the right
temporal artery is located.
4.4. HOW TO PROPERLY USE THE THERMOMETER IN
TYMPANIC (EAR) MODE
SEE DIAGRAM
A
PAGE 3.
Remove the temporal probe tip from the unit. For a child under one year
of age: pull the ear diagonally to the rear, to straighten the ear canal, and
gently insert the probe to take the reading. For a child over one year of
age, and adults: pull the ear back slightly and gently insert the probe
along the ear canal to take the reading.

5- MAIN FUNCTIONS

1. Display of the temperature reading in degrees Celsius or Fahrenheit:
Temperature range from 32°C to 42.9°C (89.6°F to 109.2°F).
2. Memorization of the last 30 readings taken: The temperature is
recorded.
3. Audible alert during temperature measurement based on the result.
4. Back-lit colour display to indicate and quickly interpret the diagnosis of
the temperature reading.
24
Visiomed - EasyScan VM-ZX1 - User manual - 062016

6- DESCRIPTION OF THE UNIT

B
SEE DIAGRAM
PAGE 3.
1
Temporal measurement probe
3
LCD Screen
5
°C/°F button
7
Battery

7- LCD SCREEN DISPLAY

SEE DIAGRAM
C
PAGE 3.
1
Tympanic Mode / Temporal Mode
2
Ambient air
3
Viewing the measurement mode.

8- SUGGESTIONS BEFORE MEASURING

1. Replace batteries that are too drained to effectively power the unit.
2. For a proper reading, condition the thermometer by placing it in the
environment where the measurement will be taken 30 minutes before
use
3. An unexpected fluctuation of the ambient temperature may distort the
accuracy of the reading. For example, if the temperature of the place
where the measurement is taken is different from the temperature
where the thermometer is stored, when one wants to take a tempe-
rature reading near an air conditioner. The results will be unreliable.
4. The measurement should be taken at rest, to yield accurate results.
Body temperature is likely to increase just after exercise or after a bath.
5. Before taking a temperature, in order to obtain a stable, reliable result
5.1 Temporal mode:
- Take care to brush away the hair.
- Wipe any sweat from the brow.
- Avoid air flows (e.g. supplemental oxygen, air conditioning, etc.).
- Wait a period of 1 minute between readings.
- With each change of environment having a high ambient tempera-
ture difference, leave the thermometer at this ambient temperature
for at least 30 min before use.