User Menu; Stove State; Pellet Manual Load; Pellet Load Correction - Bio Bronpi Elsa Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
The following table shows the meaning of the different leds of the display of the stove. The lighting of the leds indicates the activation of the
corresponding device according to the following list:
LED
L1
L2
L3
L4
L5
L6
L7
9.3.

USER MENU

9.3.1.

STOVE STATE

When the stove is switched on, by pressing key P1 of the display, it is possible to access the following options that give us some technical
information of the stove. The lower display shows the information (tA, tF, FL, UF, etc) and the upper display shows the value (ºC, rpm, sec,
etc.).
INFORMATION
tA
tF
Tr
FL
UF
Co
St
St2
FC
9.3.2.

PELLET MANUAL LOAD

If during the operation of the stove, it runs out of fuel, in order to avoid any
problem during the next ignition, it is possible to carry out a preload of pellet of
the auger during a maximum time of 300 seconds when the stove is switched off
and cold and the door is closed. A long press of key P2 starts the preload. The
lower display will show the message "LoAd", and the upper display will show the
seconds elapsed. In order to interrupt the load, press any key.
Before proceeding with a new ignition of the stove, do not forget to empty the
burner in order to avoid a dangerous situation (see drawing D27).
9.3.3.

PELLET LOAD CORRECTION

In order to access to the modification mode, it is necessary to press for a while
key P2 and, later, press again P2 for a while. The lower display shows the message
"Pell" and the upper display shows the value introduced. By using keys P2 and
P4, it is possible to increase or decrease the value introduced. The original value
introduced is 0 and it goes from -7 ... to ...+7. Note that each numerical value
modified is equal to modify proportionally in all the powers a 2% of the load time
value (in seconds) set for the auger. After 5 seconds, the new value will be saved
and the display will return to the normal state.
Consider that a higher pellet load means a higher thermal power of the stove and,
therefore, a higher fuel consumption. If you observe that the stove is not burning
properly or the mix air/fuel is not appropriate, try to modify the fuel load (see
drawing D28).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
S
G
W
Room temperature of the base (ºC)
Smoke temperature (ºC)
Remote air temperature (ºC)
Flow speed of the primary air (cm/sec)
Smoke extractor speed (rpm)
Auger activation time (sec)
Remaining time until maintenance service 1(h)
Remaining time until maintenance service 2 (h)
Code and firmware version.
FUNCTION
Led On: heating fan activated
Led On: auger activated
Led On: ignition resistor activated
Led On: thermostat temperature reached
Led On: daily programming
Led On: weekly programming
Led On: weekend programming
VALUE
ESC
ESC
33
30
LoAd
GS
W
0
peLL
GS
W
D27
D28
ELSA