The following table shows the meaning of the different leds of the display of the stove. The lighting of the leds indicates the activation of the
corresponding device according to the following list:
LED
L1
L2
L3
L4
L5
L6
L7
9.3.

USER MENU

9.3.1.

STOVE STATE

When the stove is switched on, by pressing key P1 of the display, it is possible to access the following options that give us some technical
information of the stove. The lower display shows the information (tA, tF, FL, UF, etc) and the upper display shows the value (ºC, rpm, sec,
etc.).
INFORMATION
tA
tF
Tr
FL
UF
Co
St
St2
FC
9.3.2.

PELLET MANUAL LOAD

If during the operation of the stove, it runs out of fuel, in order to avoid any problem
during the next ignition, it is possible to carry out a preload of pellet of the auger
during a maximum time of 300 seconds when the stove is switched off and cold
and the door is closed. A long press of key P3 starts the preload. The lower display
will show the message "LoAd", and the upper display will show the seconds
elapsed. In order to interrupt the load, press any key.
Before proceeding with a new ignition of the stove, do not forget to empty the
burner in order to avoid a dangerous situation (see drawing D34).
9.3.3.

PELLET LOAD CORRECTION

ESC
peLL
GS
D35
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
S
G
W
Room temperature of the base (ºC)
Smoke temperature (ºC)
Remote air temperature (ºC)
Flow speed of the primary air (cm/sec)
Smoke extractor speed (rpm)
Auger activation time (sec)
Remaining time until maintenance service 1(h)
Remaining time until maintenance service 2 (h)
Code and firmware version.
In order to access to
the modification mode, it is necessary to press for a while key P2 and, later, press
0
again P2 for a while. The lower display shows the message "Pell" and the upper
display shows the value introduced. By using keys P2 and P4, it is possible to
increase or decrease the value introduced. The original value introduced is 0 and it
goes from -7 ... to ...+7. Note that each numerical value modified is equal to modify
proportionally in all the powers a 2% of the load time value (in seconds) set for the
auger. After 5 seconds, the new value will be saved and the display will return to
the normal state.
Consider that a higher pellet load means a higher thermal power of the stove and,
therefore, a higher fuel consumption. If you observe that the stove is not burning
properly or the mix air/fuel is not appropriate, try to modify the fuel load (see
W
drawing D35).
FUNCTION
Led On: heating fan activated
Led On: auger activated
Led On: ignition resistor activated
Led On: thermostat temperature reached
Led On: daily programming
Led On: weekly programming
Led On: weekend programming
VALUE
ESC
39
30
LoAd
GS
W
ELSA AND PAULA
D34

Publicité