Material Composition And Recyclability; Fuel Cell Model - Operating Instructions - Nilfisk Advance 56511710 Mode D'emploi

Masquer les pouces Voir aussi pour Advance 56511710:
Table des Matières

Publicité

A - ENGLISH

Material Composition and Recyclability

Type
Aluminum
Electrical / motors / engines - misc
Ferrous metals
Harnesses / cables
Liquids
Plastic - non-recyclable
Plastic - recyclable
Polyethylene
Rubber
CS7010 FUEL CELL MODEL – OPERATING INSTRUCTIONS
Operation:
Do not turn the fuel cell module off while the machine is in operation! Always turn the machine off fi rst, and then turn the fuel cell
module off.
For operating, refueling, safety, or service information specifi c to the fuel cell module, refer to the manufacturer's publications.
The following fuel cell hybrid modules have been evaluated and are approved for use in this equipment:
Plug_Power, Inc. model 2300 Gen-Drive hybrid fuel cell module
For operating, safety, or service information specifi c to the CS7010, refer to the appropriate Nilfi sk documentation.
Cleaning of Machine:
FUEL CELL MODULE SHOULD NOT GET WET! Cleaning of the CS7010 should be done in accordance with instructions in the
machine operating manual with the following important note: The fuel cell module should not be subjected to water or solution spray or
indirect contact.
Do not spray or pour water over the top of the machine as liquid may run between machine panels onto the fuel cell module.
Keep water spray below the fuel cell compartment.
Do not spray water or solution into the side grille openings.
Fuel Cell Installation or Removal:
Follow standard battery installation and removal procedures. Module must be installed or removed using a battery roll-out cart with
minimum capacity rating of 2300 LBS (1050 kg).
Install the module with the refueling port on the operator side of the machine.
Installation or Removal of Fuel Cell Module User Interface Panel:
Refer to "Fuel Cell Module User Interface Panel" instruction sheet.
A - 52
INSTRUCTIONS FOR USE
% of machine weight
Petrol / LPG
0.5%
27%
53.8%
1.1%
0.7%
1.5%
0.9%
12%
2.5%
Limitations: The fuel cell module listed above is intended for use in normal warehouse or other moderate-duty
applications. It is intended for indoor use only. It may not be suitable for severe-duty applications such as rough
surface cleaning/sweeping or severe inclines.
CS7010 - 56091206
% of machine weight
% of machine weight
Diesel
0.5%
29.3%
51%
1.2%
0.7%
1.8%
0.7%
12.3%
2.5%
% recyclable
Battery
0.3%
88%
50.1%
95%
35.2%
95%
0.9%
74%
0.9%
95%
1.1%
0%
0.4%
91%
9.2%
100%
1.9%
60%
4/2017