General Safety; Technical Specifications; Preliminary Checks; General Outline - BFT PHOBOS L Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336/EEC and
73/23/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

Electromechanical piston designed to automate residential type gates.
The gearmotor keeps the gate blocked on closing and on opening, without
needing an electric lock for leaves up to 3 m long.
For leaves ranging from 3m to 5m long, the electric lock becomes indi-
spensable
The operator has no mechanical clutch. It must be controlled by an electronic
INSTALLATION MANUAL
control panel provided with torque setting. The end-of-stroke operation is
managed by the control panel.

3) TECHNICAL SPECIFICATIONS

Power supply : .....................................single-phase 230V
Motor revolutions : ......................................................................2800 min
Absorbed power : ............................................................................... 210 W
Capacitor : ......................................................................................... 6.3 µF
Absorbed current : ............................................................................... 0.8 A
Insulation class : ........................................................................................ F
Thermal protection : .................................................. 110 °C (self-resetting)
Pushing and towing force : ...............................................2000 N (~200 kg)
Max working stroke: ........................................................................
Speed : .............................................................................. approx. 13 mm/s
Impact reaction : ......................................Electronic clutch on control panel
Manual manoeuvre : .......................................................... CLS release key
No. manoeuvres in 24 hours : ..............................................60 manoeuvres
Maximum leaf length without electric lock : ........................................... 3 m
Maximum leaf length with electric lock: ................................................. 5 m
Maximum leaf weight : ......................................................2500 N (~250 kg)
Environmental conditions : ........................................from -10 °C to + 50 °C
Degree of protection : ..........................................................................IP X4
Dimensions : .................................................................................. See fig.1
Operator weight : .....................................................................77N (~7.7kg)
Lubrication : .................................................................... permanent grease
(*) Available in all power supply voltages.
4) INSTALLATION OF THE ACTUATOR

4.1) Preliminary checks

Check that:
• The gate structure is sufficiently sturdy.
• Also make sure that the actuator pushes against the leaf reinforced section.
• The leaves move manually and without effort all along their stroke.
• The door stop plates are fitted at the end of both closing and opening
strokes.
• If the gate has not been recently installed, check the wear condition of all
components.
• Repair or replace faulty or worn parts.
The automation reliability and safety are directly influenced by the state
of the gate structure.
The diagram in fig. 2 should be used as a reference for installation and
3,5
mm.
consult the table for the distances in mounting the gate post.
The diagram in fig. 2 uses the following legend:
P
Gate post rear fastening bracket
F
Front leaf fastening bracket
a-b
"P" bracket installation value
C
Distance between fixing points (C = 840 mm)
D
Gate length
X
Distance from gate axis to the edge of the post
Z
Always over 45 mm (b - X)
kg
max. weight of leaf
α°
leaf opening in degrees
4.2)
How to read the installation distance tables
Select "a" and "b" according to the angle in degrees α° that the gate has
to open.
If there is too large a difference between "a" and "b", the leaf will not travel
smoothly and the pushing or pulling force will fluctuate during its stroke.
To respect the opening speed and ensure the controller operates correctly,
it is best to keep the difference between "a" and "b" as low as possible.
When "a" and "b" are at their maximum, the piston develops the maximum
force.
4.3)
Off-standard installations.
Fig. 3 shows an installation with a recess when there is not sufficient space
between the leaf and perimeter wall.
When the leaf's position does not allow for an "b" value listed in the table,
the leaf's hinge pivot can be shifted (fig. 4), or a recess can be made cut out
of the actual gate-post (fig. 5).
4.4)
Mounting the brackets to the gate-post and to the gate.
Fix the bracket "P" (fig. 6) to the gate-post with a good welding.
The fork "F" should be welded in the same way to the gate taking care that
the actuator can then be mounted perfectly horizontal to the line of travel
of the gate fig. 7.
If the gate operates on a slope (opening inwards with an uphill driveway), fig. 7
gives the maximum oscillations of the piston with respect to its horizontal.
ENGLISH
~
±10% 50 Hz(*)
-1
470 mm
9
PHOBOS L Ver. 02 -

Publicité