1) GENERAL OUTLINE
The DEIMOS-DEIMOS 700-DEIMOS 800F actuator offers ample installation
versatility, thanks to the extremely low position of its pinion, its compact
shape and the height and depth adjustments available. The adjustable me-
chanical clutch ensures antisquash safety and provides smooth progressive
starting operations. The emergency manual release manoeuvre can be
carried out very easily by means of a knob supplied with a standard key, or
an optional personalised key.
The DEIMOS 800F series is provided with an
electromagnetic-type motor brake which allows the leaf to stop with precision.
The end-of-stroke stop is controlled by electromechanical microswitches
or, for very cold areas, by proximity sensors. The control unit can be either
incorporated or fitted to a separate panel.
The gearmotor (fig. 1) comprises :
"M" Motor
"R"
Reduction gear with worm screw – worm wheel
"F"
Mechanical clutch on motor shaft
"S"
Electromechanical limiting unit or proximity sensor
"P"
Pinion with release mechanism
"C"
Control unit and capacitor

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
14 -
DEIMOS - DEIMOS 700 - DEIMOS 800F Ver. 04
INSTALLATION MANUAL
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the auto-
mation system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
Check that the specified range of temperature is compatible with the
place where the operator is to be installed.
The motor cannot be fitted on gates which incorporate doors (unless the
motor drive can work with the door open).
Take care to avoid any possible crushing, due to door movement, between
the guided part and surrounding fixed parts.
After installation, check that the setting is correct, and the protection
system and manual release work correctly.
For installation on sliding gates which incorporate pedestrians' doors,
the motor must not work when the door is left open.

3) TECHNICAL DATA

Power supply: ...................................... single-phase 220-230V 50/60Hz(*)
Motor revolutions: .......................................................................1400 min
Absorbed power ............. Deimos:................................................270W
........................................ Deimos
Max absorbed power: ..... Deimos: ....................1.9A (220-230V):3.8 A(120V)
........................................ Deimos
Capacitor: ....................... Deimos: ....................14 µF (220-230V):55 µF (120V)
........................................ Deimos
Thermal protection:......... Deimos: .................... ............................. 160 °C
........................................
Insulation class: ............................................... ...................................... F
Max leaf weight:.............. Deimos: ....................14 teeth ...... 5000N (≈500kg)
........................................
........................................ Deimos 700: ..............14 teeth ...7000N (≈700kg)
........................................
........................................ Deimos 800F: ............14 teeth ...8000N (≈800kg)
........................................ Deimos 800F-PM: ....18 teeth ...6300N (≈630kg)
Torque supplied: ............. Deimos:............................................18Nm
........................................ Deimos
Reduction ratio: ....................................................................................1/30
Output revolutions: ......................................................................... 48 min
Pinion pitch: ................................................................... 4mm (14/18 teeth)
Leaf speed: ..................... 8,5 m/min (14 teeth) ............:11m/min (18 teeth)
Impact reaction: ...............................................................mechanical clutch
Lubrication: .................................................................... Permanent grease
Manual manoeuvre: ............................................. Mechanical knob release
No. manoeuvres in 24 hours: ................................................................ 100
Control unit: ......................................................................................ALPHA
Environmental conditions: .......................................... from -15°C to +55°C
Degree of protection: ........................................................................... IP24
Dimensions: .................................................................................. See fig.2
Controller weight:............ Deimos: ....................................................... 11kg
........................................Deimos
(*) Special supply voltages on request.
ALPHA mod. control unit has been designed to control one single
operator.
Power supply: ............................................................... 220-230V 50/60Hz
Mains/low voltage insulation: ........................................ > 2MOhm, 500Vdc
Working temperature: ..................................................from -15°C to +55°C
Dielectric strength:.... ................. mains/low voltage 3750Vac per 1 minute
Gate-open warning light: ...................................................24V
Supply to accessories: .................................24V
Incorporated Rolling-Code radio receiver: .............. Frequency 433.92MHz
Coding: .............................................. Rolling-Code Algorithm to be cloned
No. combinations: ........................................................................ 4 milliard
Antenna impedance:........................................................... 50Ohm (RG58)
Max no. radio transmitters to be memorised:............................................63
Dimensions: ............................................................................see figure 19
(* other voltages available on request)
4) TERMINAL BOARD CONNECTIONS (Fig.16)
WARNING – During the wiring and installation operations, refer to the current
standards as well as principles of good technical practice.
700-Deimos 800F:
........................ 290W
700-Deimos
800F:1.5 A (220-230V) :3 A (120)
700-Deimos
800F:10 µF(220-230V):40µF (120V)
Deimos
700-Deimos
800F:. ......................110 °C
Deimos PM:
.............18 teeth ...3800N (≈350kg)
Deimos 700 PM:
......18 teeth ...5500N (≈550kg)
700-Deimos
800F:..........................20Nm
700-Deimos
800F: .......................... 15kg
, (0.2A max absorption)