Malfunction: Causes And Remedies - BFT DEIMOS Instructions D'utilisation Et D'installation

Actionneur pour portails coulissants a cremaillere
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
ENGLISH
Have a qualified technician (installer) check the correct torque limit setting.
When any operational malfunction if found, and not resolved, disconnect
the mains power supply and request the assistance of a qualified tech-
nician (installer). When the automation controller is out of service, you
can activate the manual release device (see paragraph on "Emergency
manoeuvre") in order to set the pinion idling and therefore allow the gate
to be opened and closed by hand.
28) NOISE
The environmental noise produced by the gear-motor in normal operation
conditions is constant and does not exceed 70 dB (A).
29) SCRAPPING
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out
by type (electrical components, batteries, copper, aluminium, plastic etc.).
30) DISMANTLING
When the automation system is disassembled to be reassembled on another
site, proceed as follows:
• Disconnect the power supply and the entire external electrical installation.
• In the case where some of the components cannot be removed or are
damaged, they must be replaced.

31) MALFUNCTION: CAUSES and REMEDIES

31.1) The gate does not open. The motor does not turn.
1) Check that the photocells or the sensitive edges are not dirty, engaged,
or not aligned. Proceed accordingly.
2) Check that the electronic appliance is correctly supplied. Check the
integrity of the fuses.
3) Check that the functions are correct by means of the control unit diagno-
sing LEDs (see relevant instructions).
Identify causes for faults, if any. If the LEDs show persisting start control,
check that no radio controls, start buttons or other control devices keep
the start contact activated (closed).
4) If the control unit does not work, it must be replaced.
If after having carried out the checks listed above the problem persists,
replace the actuator.
31.2) The gate does not open. The motor turns but the movement does
not take place.
1) The manual release is activated. Reset the power-driven operation.
2) Check that the gate had reached the mechanical end-of-stroke stops.
Release and move the gate manually, and reset the power-driven control.
Check and correct the end-of-stroke bracket position.
3) Check that the mechanical setting of the gate is not defective, for example
if the wheels are blocked or the rack is not aligned with the pinion, etc.
4) Check that the clutch does not slip. If it does, load it as described in
the
relevant paragraph.
If after having carried out the checks listed above the problem persists,
replace the actuator.
WARNING! Correct controller operation is only ensured when the data
contained in the present manual are observed. The company is not to
be held responsible for any damage resulting from failure to observe
the standards relating to safety, installation and good technical practice,
as well as the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
18 -
DEIMOS - DEIMOS 700 - DEIMOS 800F Ver. 04
INSTALLATION MANUAL

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Deimos 700Deimos 800fDeimos-deimos 700

Table des Matières