GATE MOVEMENTS

Radio START
button
Gate status
or
START input
Closed
Totally opens
During
Stops opening
opening
Open
Closes
During
Stops closing
closing
Closed
Totally opens
Stops opening
During
and closes after
opening
TCA
Open
Closes
During
Stops closing
closing
(*) If the motor finds a fixed obstacle, it runs the clearance manoeuvre�

FINAL CHECKS AND MAINTENANCE

Before the automated system is finally put into operation, and during maintenance work, perform the following checks
meticulously:
- Affix a door/gate identification plate, also affix a warning sign on the frame�
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more
specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding
parts�
- Make sure the motor automation settings are correct and that the safety and release systems are working properly�
- Make sure all components are fastened securely;
- Check starting and stopping operations in the case of manual control;
- Check that the rack and pinion mesh correctly with 2 mm of play along the entire rack; keep the track the gate slides
on clean and free of debris at all times�
- Make sure all safety devices are in good working order (photocells, sensitive edges, etc�) and that safety devices are
correctly adjusted�
- Impact forces can be reduced by using deformable edges�
- Make sure that the emergency operation works, where this feature is provided�
- Check opening and closing operations with the control devices applied�
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands
are undamaged�
- While performing maintenance, clean the photocells' optics�
- When the automated system is out of service for any length of time, activate the emergency release so that the op-
erated part is made idle, thus allowing the gate to be opened and closed manually�
- The maintenance described above must be repeated at least once yearly or at shorter intervals where site or install-
ation conditions make this necessary�
44
- IANUS BT 300 KIT - IANUS BT 500 KIT
Radio
PEDESTRIAN
OPEN input
button
Semi-automatic logic (TCA = Off) - 4 steps
If the gate is
closed (closing
limit switch) it
Totally opens
partially opens,
or fully opens
Stops opening
No effect
Closes
No effect
Stops closing
Stops closing
and reverses
movement�
Automatic logic (TCA = On) - 4 steps
If the gate is
closed (closing
limit switch) it
Totally opens
partially opens,
or fully opens
Stops opening
and closes after
No effect
TCA
Closes
No effect
Stops closing
Stops closing
and reverses
movement�
Opening limit
Closing limit
switch trigger
switch trigger
No effect
No effect
Stops opening
No effect
No effect
No effect
No effect
Stops closing
No effect
No effect
Stops opening
and closes after
No effect
TCA
No effect
No effect
No effect
Stops closing
STOP input
Photocell trigger
Inhibits
Inhibits opening
movement
Inhibits
Stops opening to
movement
clearance
Inhibits
Inhibits closing
movement
Stops closing and
Inhibits
reverses movement
movement
after clearance
Inhibits
Inhibits opening
movement
Inhibits
Stops opening to
movement
clearance
Inhibits
Inhibits opening
movement
Stops closing and
Inhibits
reverses movement
movement
after clearance
Amperostop
trigger
(*)
No effect
Stops and
movement
is reversed
for 1s
No effect
Stops and
movement
is reversed
for 1s
No effect
Stops and
movement
is reversed
for 1s
No effect
Stops and
movement
is reversed
for 1s