Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WIRING DIAGRAM

*
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command�
Add Pedestrian Key
S2
associates the desired key with the pedestrian command�
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory�
Pressed BRIEFLY, it gives the START command�
S3
HELD DOWN (>5 sec�), it activates the AUTOSET function�
*
1
TRIMMER
Description
T1
Waiting time before automatic closing
2
*
LEDS
Description
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
Unlit: leaf fully closed
SWC
Lit: motor limit switch is disengaged
Unlit: leaf fully open
SWO
Lit: motor limit switch is disengaged
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting
for hidden key�
RADIO
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key�
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast flashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
*
*
27
26
25
24
*
4
*
2
*
1
N
F1
L
F1: 800 mAT
3
Terminal
L
Single-phase power supply
N
8
Flashing light 24V max� 25W
9
Antenna input�
10
Use an antenna tuned to 433MHz� Use RG58 coax cable to connect
the Antenna and Receiver� Metal bodies close to the antenna can
interfere with radio reception� If the transmitter's range is limited,
11
move the antenna to a more suitable position�
12
Accessories power supply output�
13
16
Tested safety device power supply output (photocell transmitter
and safety edge transmitter)�
17
Output active only during operating cycle�
START command button (N�O�)�
18
Operation according to "3/4-STEP" logic
19
START and OPEN inputs common
OPEN command button (N�O�)�
Gate opened with this command� If the input stays closed, the
20
leaves stay open until the contact is opened�
When the contact is open, the automated device closes following
the TCA time, where activated�
21
STOP and PHOT inputs common
The command stops movement� (N�C�)
23
If not used, leave jumper inserted�
PHOTOCELL 1 input (N�C�)�
24
If not used, leave jumper inserted�
25
Test input for safety devices connected to PHOT
PHOTOCELL 2 input (N�C�)�
26
If not used, leave jumper inserted�
27
Test input for safety devices connected to PHOT
4
DIP-SWITCH
ON: Switches photocell 1 testing on
1
OFF: Switches photocell 1 testing off
ON: Switches photocell 2 testing on
2
OFF: Switches photocell 2 testing off
ON: Activates automatic closing
3
OFF: Excludes automatic closing
ON: Motor installed on the left
4
OFF: Motor installed on the right
5
Not used
6
Not used
7
Not used
8
Not used
9
Not used
10
Not used
23
22
21
20
19
18
17
16
15
14
13
ON
1 2 3 4
5 6 7 8 9 10
*
Description
220-230V ~50/60 Hz
1�
2�
Description
3
*
12
11
10
9
8
7
6
5
4
3
2
F2
F2: 3,15 AT
IANUS BT 300 KIT - IANUS BT 500 KIT
1
43
-

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ianus bt 500 kit

Table des Matières