Always specify the exact pump/electric pump type and identification code (fig. 14) when requesting technical
information or spare parts from our Sales and Service department. Use only original spare parts to replace any worn
or faulty components. The use of unsuitable spare parts may cause malfunctions, damage and injuries. For any other
situation not contemplated in the table, refer to our Sales and Service Department.
Problem
The electric pump does not start.
The electric pump starts up but the
thermal protector is triggered after a
short time or the fuses blow.
The motor starts but the pump does
not deliver.
The pump's delivery is reduced.
9
Disposal (of packaging and product)
Observe the regulations and codes locally in force regarding sorted waste disposal.
10
Maximum head and noise
See tables 11 and 12.
11

EC DECLARATION OF CONFORMITY

LOWARA SRL UNIPERSONALE, WITH HEADQUARTERS IN VIA LOMBARDI 14 - 36075 MONTECCHIO
MAGGIORE (VI) - ITALIA, HEREBY DECLARES THAT THE PRODUCT
FULFILS THE RELEVANT PROVISIONS OF THE FOLLOWING EUROPEAN DIRECTIVES
MACHINERY 2006/42/EC (THE TECHNICAL FILE IS AVAILABLE FROM LOWARA SRL UNIPERSONALE).
ELECTROMAGNETIC COMPATIBILITY 2004/108/EC
AND THE FOLLOWING TECHNICAL STANDARDS
EN 809, EN 60335-1, EN 60335-2-41
EN 61000-6-1:2007, EN 61000-6-3:2007
IF THE PUMP IS A BGM GARDEN, IT ALSO FULFILS THE FOLLOWING DIRECTIVE 2000/14/EC
-
CLASSIFIED AS WATER PUMP ACCORDING TO ANNEX I TO THE DIRECTIVE,
-
SUBJECT TO THE INTERNAL CONTROL OF PRODUCTION PROCEDURES REFERRED TO IN ANNEX V TO
THE DIRECTIVE,
Probable cause and possible solutions
The thermo-amperometric protection incorporated
in the single-phase versions may have activated: it
will reset automatically once the motor has cooled.
Check the power supply and ensure connection to
the mains is intact.
Reset the ground fault interrupter or circuit breaker
if it has triggered. Replace any blown fuses.
Triggering of protection device against dry running.
Check the water level in the tank, the protection
device and the respective connecting cables.
Power supply cable is damaged, electric motor
short circuit, thermal protector or fuses not suited
to the motor current Check the components and
replace as necessary.
Triggering of thermoamperometric protection
(single-phase version) or of the protection device
(three-phase version) due to excessive current
input. Check the pump working conditions.
A phase in the power supply is missing. Check the
power supply
There are foreign bodies (solids or filaments)
inside the pump, the impellers are jammed. Clean
the pump.
The pump is sucking in air. Check the liquid level,
the tightness of the suction pipe and the operation
of the foot valve.
Pump not correctly primed. Repeat the procedure
of filling the pump body.
Check for throttling of the pipes.
Wrong rotation direction (three-phase models).
Check the direction of rotation.
Pump not correctly primed. Repeat the procedure
of filling the pump body.
ELECTRIC PUMP UNIT (SEE LABEL ON FIRST PAGE)
8
X
X
X
X
X
X
X
X
X
X
X
X
X
X
« TRANSLATION »