Dangers Of Non-Observance Of The Safety; Instructions; Safety Instructions For The Operator / Worker; Safety Instructions For Maintenance, Inspections And Mounting Work - Lowara TDB Série Instructions Pour L'installation Et L'emploi

Pompes centrifuges multicellulaires verticales
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
Installation, Operating and Maintenance Instruction

2.2 Dangers of non-observance of the Safety

Instructions

Non-observance of the Safety Instructions can
lead to loss of any claim for damages.
Further, non-observance can lead to following risks:
Failure of important functions of the machine or
facility.
Failure of electronic appliances and measuring
instruments by magnetic fields.
Endangering of persons and their personal
property by magnetic fields.
Endangering of persons by electric, mechanic and
chemical influences.
Endangering of environment through leakage of
dangerous substances.

2.3 Safety Instructions for the Operator / Worker

Depending on the operating conditions, wear and
tear, corrosion or age will limit the working life of
the
pump/pump
characteristics. The operator must ensure that
regular inspection and maintenance are carried
out so that all parts are replaced in good time,
which
would
otherwise
operation of the system. If abnormal operation or
any damage is observed, the pump must cease
operation immediately.
If the breakdown or failure of any system or unit
could lead to people being hurt or property being
damaged, such system or unit must be provided
with alarm devices and/or spare modules, and
they should be tested regularly to ensure that they
function properly.
If there is any risk of injury from hot or cold
machine parts, these parts must be protected
against contact by the user, or suitable warning
signs must be affixed.
Contact protection on moving parts (e.g. coupling
guards) must not be removed from systems that
are in operation.
If the sound level of a pump or pump unit is above
85 dB(A) an ear protection has to be used when
staying near the pump for some time.
If dangerous media (e.g. explosive, toxic, hot) leak
out (e.g. from shaft seals), these must be directed
away so that there is no danger to people or the
environment. The provisions of the law must be
observed.

3. Description

3.1 Models

TDB design: Multi-stage block pump with vertical
shaft, drive-side grease-lubricated rolling bearing
(=motor bearing), radial medium-lubricated slide
bearing in the intake casing of the pump.
TDV design: Vertical multi-stage pump with its own
axial bearing with grease lubrication and relubrication
mechanism; standard motors as per IEC, design V1,
output from 90 kW to 355 kW; power transfer via
elastic
coupling;
radial
TDB, TDV
unit,
and
its
specified
endanger
the
medium-lubricated
page 55
Measures should be taken to exclude any danger
from electricity (e.g. by complying with the local
regulations on electrical equipment). If work is
carried out on live electrical components, they
should be unplugged from the mains or the main
switch turned off and fuse unscrewed. A motor
protection switch is to be provided.
2.4
Safety
Inspections and Mounting Work
The operator is responsible that any maintenance,
inspections and mounting work is made by
authorized competent personnel, which must be
informed
Instructions.
Basically, all work on the pump or pump unit
should only be carried out when the pump is
stationary and not under pressure. All parts must
be allowed to return to ambient temperature.
Make sure that no-one can start the motor during
such work. It is essential that the procedure for
stopping the system described in the Operating
Instructions is observed. Pumps or pump systems
that carry media that are dangerous to health must
safe
be decontaminated before being taken apart.
Safety Data Sheets for the various liquids handled.
Immediately after finishing work, all safety and
protective devices must be replaced or restarted.
2.5 Unauthorized Alteration and Spare Parts
Production
Alteration or changes of the machine are permitted
after agreement with the manufacturer.
Original spare parts and accessory authorized by the
manufacturer are serving the safety.
The use of other parts can lead to loss of liability for
there from resulting consequences.

2.6 Undue Operation

The operating safety of the delivered machine can
only be guaranteed by designated use acc. to the
following chapters of the Operating Instructions. The
limits stated in the data sheet and / or order
confirmation must not be exceeded under any
circumstances.
bearing in the intake casing of the pump; bearing and
shaft seal replaceable without disassembly of the
pump body.
Installation position: Shaft vertical. Installation
positions deviating therefrom must be approved by the
manufacturer.
The pumps are designed as modular systems and
can, therefore, be delivered in many variants (e.g.
different materials, shaft sealings, different kinds of
lubrication, cooling / heating, a.s.o.).
slide
Model TDB, TDV
Instructions
for
by
having
read
the
Maintenance,
Operating
Revision 01
Issue 06/2012

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tdv série

Table des Matières