Installation, Operating And Maintenance Instruction; Bearings; Approximate Value For Sound Pressure Level; Permitted Nozzle Loads And Torques At The Pump Nozzles - Lowara TDB Série Instructions Pour L'installation Et L'emploi

Pompes centrifuges multicellulaires verticales
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36

Installation, Operating and Maintenance Instruction

The permitted application conditions and design
details of the delivered pump are shown in the
attached data sheet and / or order confirmation.

3.2 Bearings

TDB design: Drive-side in the rolling bearings of the
motor. The bearings have lifetime grease lubrication
so that no maintenance is required.
TDV design: Drive-side: Pressure-side angular ball
bearing (fixed bearing) with relubrication mechanism
(lubrication nipple)
Bearing types
Pump Size
TDV..... (120)
TDV..... (170)
TDV..... (220)
TDV..... (280)
TDB and TDV designs:
Intake-side: Medium-lubricated slide bearing in the
intake casing of the pump.
The pump-side slide bearing is lubricated by the
pumped medium.

3.3 Approximate Value for Sound Pressure Level

Sound pressure level L
Nominal
power
Pump alone
P
2950
1450
N
-1
in kW
min
min
1,5
66,7
2,2
68
3
69
4
69,9
5,5
71
7,5
71,9
11
73,3
15
74,2
18,5
74,9
22
75,5
30
76,5
37
77,1
45
77,9
55
78,5
75
79,4
90
80,1
110
80,8
132
81,3
160
81,9
200
82,7
250
83,4
315
84,1
355
84,6
Sound pressure level L
from pump surface acc. to DIN 45635, part 1. Room
and foundation influences are not considered. The
tolerance for these values is ± 3 dB(A).
TDB, TDV
Grease Lubrication
Drive-side Bearing Type
2x 7308 (X arrangement)
2x 7308 (X arrangement)
2x 7310 (X arrangement)
2x 7310 (X arrangement)
in dB(A)
pA
Pump + Motor
2950
1450
-1
-1
min
min
65,8
68,2
66,0
67
69,2
67,2
68,1
71,5
68,3
69
72,1
69,2
70
73,1
70,4
71
73,7
71,3
72,3
75,0
73,2
73,3
75,6
74,0
74
76,1
74,6
74,5
77,1
75,1
75,6
77,8
76,1
76,2
78,3
76,8
76,9
79,4
77,4
77,5
80,1
78,0
78,5
81,4
78,9
79,1
81,8
79,4
79,8
83,4
80,2
80,4
83,7
80,8
81
84,1
81,3
84,6
86,2
86,6
86,9
measured in 1 m distance
pA
3.4 Permitted Nozzle Loads and Torques at the
Pump Nozzles ...
The individual forces and individual torques as well as
collective forces and collective torques given in the
table may not be exceeded.
F
=
M
=
Permissible Forces / Torques on the DNS Suction
Dimension
TDB 22
-1
TDB 35
DNS 65
TDB 58
TDB 78
DNS 100
TDB 120
TDB 170
TDV 120
TDV 170
DNS 125
TDV 220
TDV 280
DNS 150

General Instructions:

Direction of the forces and torques:
Fx ...Force in direction of the x-axis (pump shaft)
page 56
Model TDB, TDV
2
2
2
(
Fx
+
Fy
+
Fz
)
[
2
2
2
(
Mx
+
My
+
Mz
)
TDB, TDV design
Joints
Horizontal Suction
Joints,
Any Location
Fx
560
Fy
510
Fz
620
980
∑F
Mx
350
My
200
Mz
260
480
∑M
Fx
900
Fy
810
Fz
1010
1580
∑F
Mx
440
My
260
Mz
330
610
∑M
Fx
1130
Fy
1010
Fz
1250
1970
∑F
Mx
570
My
350
Mz
440
800
∑M
Fx
1350
Fy
1220
Fz
1500
2360
∑F
Mx
700
My
440
Mz
540
990
∑M
N
]
[
Nm
]
Revision 01
Issue 06/2012

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tdv série

Table des Matières