8.2 Inverter maintenance and update procedures
To restart or decommission the inverter completely, please follow the steps below.
8.2.1
1- Switch all protective devices to OFF position in the following order.
2- Wait for the LCD display of the inverter to shut down (maximum 30sec)
FR
8.2.2
1- Unplug the PV, Batteries, AC GRID and AC BACKUP connectors
FR
EN
2- Disconnect the ground cable from the inverter
ES
3- Disconnect the communication cables (Ethernet, CAN etc.)
4- Unscrew the 2 support screws fixing the inverter to the wall mounting plate
5-
Remove the inverter from the wall mounting plate
8.2.3
1- Place the inverter on the wall mounting plate
2- Screw the 2 support screws fixing the inverter to the wall mounting plate
3- Connect the communication cables (Ethernet, CAN etc.)
4- Connect the ground cable of the inverter
5- Make sure that all protective devices (PV switch, battery switch and AC breakers) are in the
OFF position.
6- Plug the PV, Batteries, AC GRID and AC BACKU connectors
8.2.4
1- Switch all protective devices to ON position in the following order.
92
Manuel d'installation / Installation guide IMEON Inverter/ Guia de montaje – Rev C.14
IMEON INVERTER
Shutdown the inverter
PV switch
Battery switch
AC breakers
Uninstall the inverter
Reinstall the inverter
Restart the inverter
AC breakers
Battery switch
PV switch