4. Inverter supervision

4.1 LCD Information

NOTE: Press any button to turn the display on.
Display :
Indicator
Manuel d'installation / Installation guide IMEON Inverter/ Guia de montaje – Rev C.14
Detail
Indicates AC BACKUP active power, apparent
power, frequency and voltage
kW: Active Power L1N, L2N, and L3N.
kVA: Apparent power L1N, L2N, and L3N.
Hz: Frequency L1N, L2N, and L3N.
V: Voltage L1N, L2N and L3N.
Indicates BATTERY voltage, charge current and
percentage of charge
A: Current.
V: Voltage.
% : percentage of charge (displayed for
information only because it depends on
several parameters)
Indicates AC GRID input voltage and frequency.
V: Voltage L1N, L2N and L3N.
Hz: Frequency L1N, L2N and L3N.
Indicates PV input voltage and power.
Today kWh: Today Production.
Total kWh: Total Production.
Indicates the generated PV production of both
DC INPUT P1 and P2.
kW: Active power.
A: Current.
V: Voltage.
Indicates the PV MPPT P1 and P2 of both MPPT
trackers. If any of the icons flashes, that means
that the dedicated array is unavailable.
Indicates the grid.
If the icon flashes, that means the grid is
unavailable.