Before performing any maintenance, disconnect the ap-
pliance from the mains.
Regular maintenance is required for the insert to function
correctly.
Any problems resulting from lack of maintenance will im-
mediately void the warranty.

DAILY MAINTENANCE

Operations must be performed when the stove is off, cold
and unplugged from the power supply
• Cleaning must be carried out with a vacuum cleaner (see
optional extras page 58).
• Open the door, extract the fi rebox (1 - fi g. A) and tip the
residue into the ash drawer (2 - fi g. A).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PEL-
LET HOPPER.
• Remove the ash grill (3 – Fig. A), clean any debris clogging
the holes.
• Pull the ash drawer (2 - fi g. A) out and empty it into a nonfl
ammable container (the ash may still have some parts that are
hot and/or embers).
• Vacuum the inside of the fi replace, the hearth, the space
around the crucible and in the side inspections (4 - fi g. A) whe-
re the ash falls.
NB: the two ash drawers must be repositioned so as to
approach them as much as possible to the side walls where
there occur the inspections.
• Remove the fi rebox (1 - fi g. A) and remove any encrustation
using the brush provided, clearing any clogging in the holes.
• Vacuum the fi rebox, clean the contact edges between the fi re
box and its seating.
• Clean the glass, if necessary (when cold).
We remind you that using without cleaning the melting pot,
may cause a sudden ignition gas inside the combustion cham-
ber with the consequent breaking of the glass.
Never vacuum hot ash, it can make the vacuum cleaner
breakdown and represents a fi re risk.
ATTENTION:
MAKE SURE THE ASH TRAY IS CORRECTLY POSI-
TIONED IN ITS HOUSING

WEEKLY MAINTENANCE

• Clean the combustion chamber (with brush).
• Vacuum the hose located near the electrical resistance (5 -
fi g. B).
• Remove the ceiling (6 - fi g. B) and tip the residue into the ash
drawer.
N:B: reposition the ceiling with the arrow pointing out-
wards
• Clean the combustion chamber

MAINTENANCE

2
! g. A
! g. B
- 54
-
3
2
6
4
1
5