Daily Maintenance; Weekly Maintenance - EdilKamin INPELLET 54 Installation, Usage Et Maintenance

Masquer les pouces Voir aussi pour INPELLET 54:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the insert to function correctly.
LACK OF MAINTENANCE will prevent the insert from functioning properly.
Any problems resulting from lack of maintenance will immediately void the warranty.

DAILY MAINTENANCE

Clean using a vacuum cleaner and with the insert cold (see optional extras page 35).
The whole procedure will take just a few minutes a day.
- Vacuum the hatch, the fire surface, and the compartment around the combustion chamber where the ash falls.
- Remove the combustion chamber and use the metal spatula supplied to scrape off any waste. Clean out any blocked
holes on both sides.
- Vacuum the combustion chamber, clean the contacts between the chamber and its housing, replace the combustion chamber.
- Clean the glass, if necessary (when cold).
Do not vacuum up hot ash as this will damage the vacuum cleaner

WEEKLY MAINTENANCE

- Clean the hearth and the chamber under the hearth ( ) (fig. no.1).
- Remove and clean the ceiling ( ) (fig. no.2).
*
fig. 1
SEASONAL MAINTENANCE (IMPLEMENTED BY THE DEALER)
After consumption of 1000 kg of pellets, the wording 'maintenance' will appear, entailing the following:
- Clean generally inside and out
- Clean/ exchange pipe carefully
- Clean and remove dirt from combustion chamber
and relative compartment carefully
- Clean the smoke outlet "A"
(replace smoke outlet gaskets if necessary).
- Clean the smoke outlet pipe "B"
(replace smoke outlet pipe gaskets if necessary).
- Clean smoke extraction fan compartment,
flow sensor and thermo coupling control "C".
- Clean, inspect and scrape residues from the
ignition resistance compartment, replace if
necessary "D".
- Visual inspection of electrical wires, connections
and power lead
- Clean the pellet tank, removing the flange and
verify feed screw-gear motor assembly clearances
- Replace hatch seal if required
- Test function, cochlea load, ignition and function
for 10 minutes, then shutdown.
If the insert is used very frequently, the smoke
duct should be cleaned once every 3 months.
MAINTENANCE
*
32
fig. 2
C
D
B
A

Publicité

Table des Matières
loading

Table des Matières