NOTES ON FITTING THE COVERING
If using a prefabricated Edilkamin covering, In order to define the exact position of the INPELLET 54, it is impor-
tant to check which covering will be used to complete it.
Positioning differs according to the model chosen (see assembly instructions given in the packaging of each cove-
ring). Always check that installation is perfectly vertical and horizontal.
METAL FINISHING PROFILE FOR "FRAME" COATING ASSEMBLY
Open the Inpellet 54 external frame with grille and assemble the lower frame profile (X) on the lower base of the
structure, fastening it with the screws provided (see fig.6).
On the external frame with grille, replace the already-assembled lower flat profile (Y) with the lower "L" profile
provided (Z), unscrewing the 4 self-threading screws (V) and the 2 screws with nuts assembled on rods (V/1) (see
fig.6).
v/
1
v
COVERINGS, COUNTER-HOODS AND THEIR VENTILATION
Before installing the covering, check that all connections, commands and moving parts are perfectly functional.
Check this with the insert on and working for a few hours. Do so prior to fitting the covering in order to intervene
as necessary.
Finishing works, such as construction of the counter-hood, covering assembly, pilaster preparation, painting, etc.,
should be carried out once the final test has been passed.
Edilkamin will therefore not be held liable for any charges deriving from both demolition and reconstruction works,
even where consequent to replacement of any faulty insert parts.
Rather, at least 1 cm. (approx.) space must be left to allow air to flow, thereby preventing heat from accu-
mulating.
THE MANTEL CAN BE CONSTRUCTED WITH FIRE RESISTANT PANELS IN PLASTERBOARD OR
GYPSUM BOARD. AERATION GRILLES FOR PREVENTING ANY EXCESS TEMPERATURE INSIDE
MUST BE PROVIDED FOR DURING CONSTRUCTION.
During the construction phase of the covering it is fundamental to ensure that the combustion air is resto-
red to prevent pressure phenomena in the room where the fireplace is installed
(refer to the Chapter regarding the external air inlet on page 23)
In addition to the above, always consider the indications given by paragraphs 4.4 and 4.7 of standard UNI
10683/2005 "insulation, finishes, coverings and safety recommendations".