Possible Troubleshooting - EdilKamin INPELLET 54 Installation, Usage Et Maintenance

Masquer les pouces Voir aussi pour INPELLET 54:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36

POSSIBLE TROUBLESHOOTING

In the event of problems the INPELLET 54 stops automatically and runs the shutdown process and the display
shows text regarding the motivation of the shutdown (see the various alarms below).
Never pull the plug during shutdown on account of malfunction.
Should it block, to restart the insert you will need to allow the turn-off procedure to take place (600 seconds with
audible signal), and then press the button
Do not turn the stove on again before checking the cause of the malfunction and CLEANING/ EMPTYING the crucible.
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION AND INDICATIONS AND REMEDIES:
1) Verific./air flow: turns off for lack of depression (intervenes if the flow sensor detects insufficient combustion air flow).
Flow may be insufficient if there is a hatch open or the hatch is not perfectly sealed (e.g. seal flawed). This may also be
the case if there is a problem with air intake or smoke extraction, or if the combustion chamber is blocked or the flow
sensor dirty (clean with dry air).
Also check that the flow sensor limits are within the parameters.
The depression alarm may also be signalled during ignition, if the chimney flue does not comply with specifications or
the chimney flue and chimney pot are clogged.
2) Verific./extract.: turns off due to smoke expulsion motor (intervenes if the smoke extractor revolutions sensor detects
an anomaly)
- Check smoke extractor function (devolution sensor connection) and board.
- Verify the electrical system and earthing system.
3) Stop/Flame: turns off due to drop in smoke temperature (intervenes if the thermo coupling reports a smoke
temperature below a value set, thereby interpreting it as a lack of flame). Flame may fail for any of the following reasons:
- lack of pellets
- too many pellets have suffocated the flame
- the maximum thermostat has intervened (rare, this only intervenes in the event of excessive smoke temperature)
4) Block_FI/NO Start: turns off due to incorrect smoke temperature during ignition (intervenes if a flame fails to appe-
ar within a maximum of 15 minutes, or if ignition temperature is not reached).
Distinguish either of the following cases:
The flame has NOT appeared
Check:
- correct positioning and cleanliness of combustion chamber
- resistance function
- room temperature (if less than 3°C) and moisture content.
- Try to ignite with Diavolina®
5) Black Out: turns off due to lack of electricity (not a defect of the insert).
Check electricity connection and drops in voltage.
6) Fault/RC: turns off due to thermo coupling failed or disconnected (intervenes if the thermo coupling has failed or
is disconnected).
Check connection of thermo coupling to board: check function in cold test.
7) smoke °C/high: turns off due to exceeding maximum smoke temperature.
Excessive smoke temperature may depend on: pellet type, anomaly in smoke extraction, smoke channel blocked,
incorrect installation, gear motor 'drift'
8) Check button: signals an anomaly on the emergency button; check maintenance status of the button and its board
connection cable.
.
The flame has appeared but after the wording Ignition,
the wording Block_FI/NO Start has appeared.
Check :
- thermo coupling function
- ignition temperature set in the parameters
33

Publicité

Table des Matières
loading

Table des Matières