Daily Maintenance - EdilKamin PELLET-BLOK Installation, Usage Et Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the fireplace to function correctly.
Any problems resulting from lack of maintenance will immediately void the warranty.

DAILY MAINTENANCE

Operations must be performed when the fireplace is off, cold and unplugged from the power supply
• Must be performed using a vacuum cleaner (see optional extras page 39).
• The whole procedure takes up a few minutes every day.
• Open the door, remove the two ash grilles (1 - fig. A/B) and empty the residue out into the ash pan (2 - fig. C).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Remove the two ceramic tiles (front and rear) from the burner (3 - fig. D).
• Take out and empty the ash pan into a fireproof container (the ash may still contain hot parts and/or embers).
• Remove the combustion burner or use the spatula to scrape it and clean out any blocked holes on all sides
• Remove the combustion burner and scrape with a spatula. Clean any obstructions in the apertures.
• Take off the front burner plate by removing the two wing nuts.
• Vacuum the combustion burner holder
• Clean the glass, if necessary (when cold).
Never suction hot ash, as this could damage the suction device and possibly cause a fire.
1
1
fig. A
fig. B
3
2
3
fig. C
fig. D
35

Publicité

Table des Matières
loading

Table des Matières