Télécharger Imprimer la page

DT SWISS R 535 ONE Manuel D'utilisation page 17

Masquer les pouces Voir aussi pour R 535 ONE:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
4. USING THE DT SWISS HIGH PRESSURE SHOCK PUMP
The DT Swiss shock pump is supplied with shocks purchased as retrofit components.
2
The DT Swiss shock pump has a pressure gauge (1) which can be used to precisely adjust the shock's
pressure. A release valve (2) allows the pressure in the shock to be reduced. A valve lever (3) on the
pump head (4) allows the shock pump to be unscrewed without any loss of pressure.
OPERATING THE SHOCK PUMP
A. Screw the pump head (4) fully onto the valve on
the shock.
B. Close the valve lever (3) (push the lever towards
the valve) and pump up the shock.
→ Closing the valve lever (3) opens the valve on
the shock.
→ Pressing the release valve (2) allows the
pressure in the shock to be reduced.
C. Open the valve lever (3) (push the lever towards
the pump tube).
→ Opening the valve lever closes the valve on
the shock. When unscrewing, no air can escape from the shock.
D. Unscrew the pump head (4) from the valve on the shock.
1
3
R 535 ONE - User Manual V2021.09
4
A
B
C
D
17

Publicité

loading