6.3 Installation of the pump
It is possible to install or service the pump
without removing the tank (Fig. 19, page
14). To remove the tank (01), release the
metal clamps (02) and disconnect the
connecting pipe (03).
Unscrew the 2 side screws to open the cover.
Fig. 18
Undo the safety screw (04) and lift the guard (05).
02
01
Fig. 19
14
04
05
03
Turn the safety valve to release any residual pressure
in the tank.
Fig. 20
Undo the top body of the pump (01) by turning it
anti-clockwise and removing it. Fill the tank (02) (10l
max) Re-install the top body of the pump.
01
02
Fig. 21
Pressurise the tank pumping with the handle until
the indicated pressure is reached: 4Bar (without
accessories), 6Bar (antistatic delivery water pipe, 30m
(98ft), WEXTUB30). Turn the handle on the body of
the pump to its safety position.
Fig. 22
MNVCWASEX_2013_EN