6.2.2 Connection to PTZ

To install electrical connections between
the products, use the communication box
by VIDEOTEC, MAXIMUS MBX or MAXIMUS
MBA, alternatively use an explosion-
proof junction box with equivalent
characteristics.
Safety
transformer
power supply
Explosion-proof
junction box
Fig. 12
The RL2 internal relay is used for connection to the
PTZ, if necessary (consult the product manual).
The RL2 relay in the PTZ can withstand a
voltage of up to 30Vac. Turn off one of the
supply poles of the solenoid valve via the
RL2 relay of the PTZ.
MNVCWASEX_2013_EN
PTZ
Solenoid valve
Connect the solenoid valve with the following
operations:
• Open the cover of the solenoid valve.
• Identify the terminals L, N.
• Connect as in the diagram below (Fig. 13, page 11).
Fig. 13
A
11