6.10 Wiper connection

Open the housing as described in the relative
chapter (6.3 Housing opening, page 7).
Identify the terminal of the wiper board.
Fig. 21
Connect the wiper board to the power supply mains
as shown in the figure.
L
~
N
Fig. 22
Pressing the button activates the wiper. When the
button is released the wiper blade will return to the
rest position.
If you have a receiver with the Wiper control
function, connect the SW, PER and COM terminals
respectively to terminals S, P and C of the board.
Nominal section of the cables used: from
0.2mm² (24AWG) up to 2.5mm² (13AWG).
12
C
S
P
P
S
C
6.11 Connect the housing
opening signalling device
Switch working voltage: 30Vac max or
60Vdc max.
Identify on the board the terminal of the tamper-
proof switch (tamper-proof switch contacts, Fig. 20,
page 11).
Carry out the connections as described in the table.
TAMPER-PROOF SWITCH CONNECTION
Contact
Description
COM
Switch common contact
NC
Normally closed contact
NO
Normally open contact
Tab. 2

6.12 Desiccant bag

Take the dessicant salt bag out of its pack and insert
it into the product.

6.13 Housing closure

Pay attention to the fixing. Tightening
torque: 1.6Nm
Close the housing following the opposite procedure
(6.3 Housing opening, page 7).