8 Pannes et solutions
ADM3 fault
ADM3
code (J1939)
fault code
SPN / FMI
(K-line)
100 / 14
10514
100 / 14
-
102 / 0
-
102 / 1
-
102 / 2
-
102 / 3
-
102 / 4
-
102 / 7
-
102 / 7
-
102 / 13
-
102 / 13
-
102 / 13
-
103 / 3
-
103 / 4
-
103 / 7
-
105 / 0
-
105 / 3
-
105 / 4
-
107 / 0
10800
107 / 3
10803
107 / 4
10804
110 / 0
-
110 / 3
-
110 / 4
-
110 / 14
10914
111 / 1
11001
111 / 3
11003
111 / 4
11004
111 / 14
11014
ADM3 operating manual rev. 10.00b
Chapitre 8
Pannes et solutions
MR2
fault code
Fault location
(K-line)
Oil Pressure (from
-
PLD/MR2)
Oil Pressure (from
12020
PLD/MR2)
Turbo Charger/
11820
Supercharger
Turbo Charger/
11818
Supercharger
Turbo Charger/
11417
Supercharger
Turbo Charger/
11415
Supercharger
Turbo Charger/
11416
Supercharger
Turbo Charger/
11876
Supercharger
Turbo Charger/
11878
Supercharger
Turbo Charger/
11873
Supercharger
Turbo Charger/
11874
Supercharger
Turbo Charger/
11875
Supercharger
Turbo Charger Speed
12616
Sensor
Turbo Charger Speed
12615
Sensor
Turbo Charger Speed
12612
Sensor
11822
Intake Air Temperature
Intake Air Temperature
11215
Sensor 1
Intake Air Temperature
11216
Sensor 1
-
Air Filter Sensor (LF_SE)
-
Air Filter Sensor (LF_SE) Open Circuit
-
Air Filter Sensor (LF_SE) Short Circuit to Ground
Coolant Temperature
12122
(from PLD/MR2)
Coolant Temperature
11515
(from PLD/MR2)
Coolant Temperature
11516
(from PLD/MR2)
Coolant Temperature
-
(from PLD/MR2)
Coolant Level Sensor
-
(KW_SE)
Coolant Level Sensor
-
(KW_SE)
Coolant Level Sensor
-
(KW_SE)
Coolant Level Sensor
-
(KW_SE)
Fault description
Oil Pressure too Low
- Check oil pump and oil circuit.
Oil Pressure too Low
Overboost Condition
Boost System
Performance
Boost Sensor "A" Circuit
Range/Performance
Boost Sensor "A" Circuit
High
Boost Sensor "A" Circuit
Low
Boost System
Performance
Bypass Valve –
Mechanical
Underboost, Control at
Limit
Underboost, Control
Deviation too High
Boost System
Performance
Circuit Low
Circuit High
Signal Timeout, no
revolution on charger 1
Temperature Too high
Circuit High
Circuit Low
Differential Pressure too
- Check wiring.
High
- Check wiring.
- Check wiring.
- Cooling-water level and
High Coolant
cooling circuit
Temperature
Sensor 1 Circuit High
Sensor 1 Circuit Low
- Cooling-water level and
Coolant Temperature too
cooling circuit
High
- Refill coolant
Low Coolant Level
- Check wiring
- Check wiring
Open Circuit
- Voltage must be larger than
2,0 V.
Short Circuit to Ground
- Check wiring.
- Refill coolant
Coolant Level too Low
- Check wiring
346
9. Fault codes
Remedial action
check.
check.
Pin
PLD/MR2
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
15/08
15/08
15/08
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
PLD/MR2
15/07
15/07
15/07
15/07
153 / 226