Hose length Ø 50 [m]
Collecting container [l]
3
Max. flow [m
/h]
Negative pressure, max. [kPa]
Power [W]
Fine filter, polyester, area [m
Efficiency, fine filter, EN 60335-2-69, Class M [%]
Filter area, HEPA filter [m
Efficiency, fine filter, EN 60335-2-69, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.
Pressure generation and air flow

Operation

Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant.
Filter cleaning:
The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use .
Cleaning the filter:
During filter cleaning, the machine should be running and the hose removed from the suction pipe.
1. Press the connector sleeve against the black stop lug on the exhaust duct or against the floor in order to produce maximum
negative pressure in the cyclone.
16
2
]
2
]
DC 1800H/DC 2800H, Art.nr. 9497-H
DC 1800 H
DC 2800 H
5
5
20
40
205
205
24
24
1285
1285
1,5
1,5
99,9
99,9
0,85
0,85
99,995
99,995
HEPA H 13
HEPA H 13
68
70