Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Description

Th e DC 5800c 5 kW is anelectric powered vacuum extractor
for use on source extraction, cleaning and material trans-
portation applications in most types of industries.
Th e extraction system functions with negative pressure (va-
cuum) that draws the air through suction casings/nozzles,
hose system, separator and fi lter system. Coarse separation
of dust occurs in the units cyclone which is a highly effi cient

Operation

Connect the machine to a suitable power source according
to the specifi cations found on the identi-fi cation label on
the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code and be at least water resistant. Check rotation
of the motor at startup. On machines equipped with a phase
reverser, incorrect rotation can be easily changed. Machines
not equipped with a phase reverser will require the service
of a qualifi ed electrician to interchange two phases in the
power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
2010-09-06
separator for larger particulate. Th e fi ne dust is separated
and contained by the units fi lter system. Separated material
is collected for disposal in the plastic sack or container at
the base of the cyclone.
Filter cleaning with reverse pulse gives long fi lter life and
constant capacity.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the fi ne
fi lter must be changed.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
level is about 5 cm under the foot valve. Th e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks.