The following safety precautions should generally be followed before starting maintenance:
1.
The machine must be disconnected from the power supply during cleaning and maintenance.
WARNING
Service must never take place inside the zone.
2.
To avoid the spread of dust, the machine must be vacuumed and wiped clean and the suction openings be blocked, for
example with plugs, before the machine is taken from the contaminated area.
3.
All machines must be considered as contaminated if they are removed from the hazardous zone. Appropriate measures must
be taken to prevent the spread of dust.
4.
At maintenance or repair, all contaminated objects that have not been cleaned satisfactorily must be disposed of. Such items
must be disposed of in dust-proof sacks in accordance with the regulations applicable to the disposal of waste.
5.
Clean the machine before disassembling.
6.
A room with filtered, forced ventilation is recommended.
7.
Clean the maintenance area in advance.
8.
Use appropriate personal protective equipment.
9.
The cyclone filter cartridge must be replaced when necessary, but at least once a year. Only use original filters, see

Consumables.

10. Overload protection. The machine is equipped with an overheating protection. If there is insufficient air flow through the unit
(due to overload), the motor will be switched off when the temperature exceeds 55°C. In these situations, it is important to
investigate the cause of the overheating. Turn off and disconnect the power supply, and then wait for the motor to cool down
(it can take up to 30 minutes).
WARNING
Do not reuse the filter after it has been removed from the machine.
The fine filter must be changed at least once a year. The HEPA filter must be replaced after approx. 300 hours of operation. Wear
a protective mask when changing the filter. Only use original filters. Release and lift off the cover. To prevent leakage of dust,
place a plastic bag over the cyclone and remove the filter cartridge. Clean the filter plate. Fit the new filter.
1
The HEPA filter is removed by opening the cover and detaching the cartridge. By gently tilting the detached motor head away
from the cyclone, a lateral pressure occurs on the HEPA filter cartridge that is attached to the motor. If necessary, repeat the
procedure until the HEPA filter falls into the fine filter cartridge. The HEPA filter and the fine filter can then be discarded. The new
filter cartridge is placed in the fine filter and is sealed when you carefully fit the cover.
The vacuum unit has an extremely long service life and requires no maintenance. The seals must be checked after approximately
1,000 hours of operation. These parts must be replaced if wear is detected.
Consumables
Description
HEPA filter
Fine filter
Inlet plug
Plastic bag
Air filter for motor cooling
18
2
Part No.
42027H
42028H
42250H
42285H
432183H
DC 1800H/DC 2800H, Art.nr. 9497-H
3