Emptying
• The container underneath the cyclone should be emptied when about 2/3 full.
• You can use the machine with or without a plastic bag in the container.
• You must clean the filters before replacing the plastic bag.
• The plastic bag must be sealed as soon as it is removed from the container.
• Only use original bags as there must be no creases around the edge of the container. This tight seal prevents the bag from
being suctioned up.
For best results:
• When attaching the plastic bag, ensure that there is no air between the plastic bag and the container.
• Ensure that air does not enter between the container and the bag when the machine is running.

Service/Maintenance

Cleaning
The machine must be switched off and unplugged before cleaning and maintenance.
Filter replacement
The fine filter must be replaced at least once a year. Only OEM filters may be used. HEPA filters must be replaced after 300
hours.
WARNING
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable
equipment.
Release and lift off the upper part for free access to the filter. Lift the filter straight up. If appropriate, fit a plastic bag over the
cyclone to prevent the dust in the filter from spreading. Check the gasket when replacing the filter. A worn gasket can allow
hazardous dust to escape. Never use old gaskets or non-OEM parts. Place used filters in a plastic bag and seal the bag. See
instructions below.
1
Motor
The typical service life of a fan motor's original brushes is 600-700 hours. The brush can be replaced. The service life of the
second brush set is approx. 400 hours, while that of the third set is approx. 300 hours. After this time, the motor is considered
worn out and should be replaced.
Regular checks
Regularly check the power cord for damage.
The machine must be tested and inspected at least once a year due to its use with hazardous materials. Worn parts must be
replaced. Never risk functionality and service life. Only use genuine parts.

Consumables

Description
Plastic bag, standard
14
2
3
Part No.
42291
DC 1800H, Art.nr. 94114-K
4