Operation

Connect the machine to a suitable power source according to
the specifi cation plate on the machine. If the electrical cord
on the machine becomes damaged it should be replaced.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
For fi lter cleaning:
1.
Start the machine.
2.
Disconnect the hose from the suction casing.
3.
Place the suction hoses free end over the fi lter clea-
ning handle.
4.
With slow, even motion open the pulse top by de-
pressing the handle. Repeat three to four times.

Service

With cleaning and maintenance on the machine, the power
cable should be disconnected from the supply.
Th e fi ne fi lter 42025 should be changed at least once per
year. Use only original spare parts. If the machine is used
with a microfi lter/HEPA fi lter, this should be changed every
300 running hours, article number 42024. Use breathing
protection when changing the fi lter. Used fi lters should be
sealed in a plastic sack and disposed of properly.
Check regularly that the electrical cable is not damaged.
Th e DC 3800c Turbo should be performance tested at
least once per year because it may be used with hazardous
materials. Worn parts must be replaced.

Accessories

Description
Plastic sack, standard
Fine fi lter, polyester
Fine fi lter, cellulose
Microfi lter
Part no
4110
42025
42026
42024
DC 3800c Turbo - 11
5.
Reconnect the hose to the suction casing.
6.
If the fi lter condition meter reads green work can
continue, if in the red, pulse clean again. If after
several repetitions, the fi lter condition still shows red
the fi ne fi lter 42025 must be changed.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
level is about 5 cm under the foot valve. Th e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks.
Never compromise the function of the DC 3800c Turbo,
use only original spare parts.
Th e turbopump has a very long maintenance free ser-
vice life. After approximately 10 000 running hours,
the radial seal between the motor and pump housing
should be greased. Bearings and seals in the motor and
turbopump should be checked and lubricated. Parts
worn beyond serviceable tolerances should be replaced
with genuine spare parts.