Operation; Service; Accessories - Dustcontrol DC 5800c PTFE 5 kW Notice Originale

Masquer les pouces Voir aussi pour DC 5800c PTFE 5 kW:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

Connect the machine to a suitable power source by fol-
lowing the specifi cations found on the serial number plate
on the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code. Check rotation of the motor at startup. On
machines equipped with a phase reverser, incorrect rotation
can be easily changed. Machines not equipped with a phase
reverser will require the service of a qualifi ed electrician to
interchange two phases in the power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running, or if the machine is equipped with a fi lter
monitor, when this is in the red area.

Service

With cleaning and maintenance on the machine, the po-
wer cable should be disconnected from the supply. Check
regularly that the electrical cable is not damaged.
Th e fi ne fi lter should be changed at least once per year.
Use only original spare parts. If the machine is used with
a microfi lter/HEPA fi lter, this should be changed every
300 running hours.Use breathing protection when chang-
ing the fi lter. Care must be taken during the fi lter change
not to expose unprotected persons to harmful dust. Used
fi lters should be sealed in a plastic sack and disposed of
properly.
Th e DC 5800c should be performance tested at least once
per year because it may be used with hazardous materials.
Worn parts must be replaced.

Accessories

Description
Plastic sacks, standard
Fine fi lter PTFE*
Fine fi lter
Microfi lter
* Please see page 2.
2011-05-12
Part no
4614
429203
4292
4422
DC 5800c PTFE 5 kW - 10
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the main
fi lter must be changed.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
level is about 20 cm under the edge of the container. Th e
plastic sack should be sealed after removal from the machine.
Use only original plastic sacks.
Never compromise the function of the DC 5800c, use
only original spare parts.
Th e turbopump has a very long maintenance free service
life. After approximately 10 000 running hours, the radial
seal between the motor and pump housing should be
greased. Bearings and seals in the motor and turbopump
should be checked and lubricated. Parts worn beyond
serviceable tolerances should be replaced with genuine
spare parts.
Other accessories — see Dustcontrol catalo-
gue.
Part No 9475

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9475

Table des Matières