Note: The size of the register data defined by the fields «CONF ID1», «CONF ID2», «CONF ID3», «etc», is variable depending
on the register number. Refer to the list of registers (see section 3.3.1) to determine the size of each register and deduce the
total size of the data returned by frame 0x31.
4.1.12

Response frame following a registry update via downlink

This frame (0x33) is transmitted following the reception of a downlink frame with the code 0x41 (see details in section 4.2.7). It allows to know
if the downlink frame (0x41) has been received and gives information on the status of its support.
0
1
0x33
Bytes
Status
status
of the
request
CAUTION: if the request 0x33 concerns several registers, the device will stop the analysis of the Downlink request at the first error and will send
the Status frame with the reason and the identifier of the register concerned.
Request status:
- 0x01: success => device restart as a result of this request
- 0x02: error - no update
- 0x03: error - coherence
- 0x04: error - invalid register
- 0x05: error - invalid value
- 0x06: error - truncated value
- 0x07: error - unauthorized access
- 0x08: error - device defect
In the event of an error, if a partial reconfiguration has taken place before the error was detected, the device restarts and returns to its last valid
configuration. As a result, you will have to configure the device again with the new data.
Registry ID: Indicates to the user the registry that caused the error (only if "Request Status" is different from 0x01).
4.1.13

Frame for acknowledgement of a 0x60 or 0x61 frame

The 0x2F frame allows the acknowledgement of a 0x60 or 0x61 frame.
0
Code
0x2F
Description of the frame :
• Byte 1: Frame status 0x2F
• Byte 2: Status of the request
0x00 = N/1
0x01 = successful
0x02 = error - generic
0x03 = error - requested state not known (other than ON or OFF)
0x04 = error - invalid request
2
3-4
Registry
identifier
1
PAYLOAD
Status
Request status
2
3 - 8
X
FR
EN
Page