Cord Attachment & Detachment

Attach the Cord (3 steps)

1. Pull the cord with the cone through the attachment
loop. (See Fig. 4 )
2. Fit the cord into the opening of the cup section (A).
(See Fig. 5 )
3. Makes sure to pull the other end of the cord so
that the cone (B) fi ts into the cup (A) tightly.
(See Fig. 6 )
Fig. 4

Applying the Sling

In Chair/Wheelchair (17 steps)

1. Place the Sara Plus lift nearby.
2. Apply the brakes on the wheelchair.
3. Lean the patient forward and place the sling around
the patient's lower back. (See Fig. 7 )
4. Position the bottom of the sling, aligned
horizontally, about fi ve centimetres (two inches)
above the patient's waistline.
5. Make sure that:
patient's arms are outside the sling,
support belt is positioned loosely around the
patient's body and
support belt is not twisted or trapped behind the
patient's back.
6. Fasten the support belt securely by pressing the
buckles or hook and loop together. The strap should
be tight but comfortable for the patient. (See Fig. 8 )
WARNING
To avoid injury to the patient, pay close
attention when lowering or adjusting the
spreader bar.
Fig. 7

Detach the Cord (3 steps)

1. Release the tension in the cord by pushing it
towards the cup.
2. Remove the cup from the cone.
3. Pull out the cord from the attachment loop.
Fig. 5
A
7. Position the Sara Plus lift in front of the patient
with its protective pad just below the patient's
knees. Open up the chassis legs, if needed. See the
Sara Plus IFU.
8. Apply the brakes on the Sara Plus.
9. Place the patient's feet on the Sara Plus foot
support.
10. Lower the Sara Plus Arc-Rest as low as possible,
allowing for obstructions e.g chair arms. See the
Sara Plus IFU.
11. Find the attachment loops on the side of the sling
and attach each cord to the loop across from it.
The cords shall not cross each other. (See Fig. 9 )
Sara Plus Flites: before the transfer of the
patient, make sure to use the relevant pair of
loop attachment in accordance with the patients
position/distance to the lift. It's recommended to
use either the innermost or the outermost pair.
WARNING
To avoid the patient from falling, make sure
that the sling attachments are attached
securely before and during the lifting
process.
Continue with the steps on the next page
Fig. 8
7
Fig. 6
B
A
Fig. 9
EN