Hydac FluidControl Unit FCU 8000-1 Série Manuel D'utilisation Et D'entretien page 91

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating and Maintenance Instruction FCU 8000-1 series
FCU 8210 :
1
2
1
The FCU is working in Mode M1 (measuring the cleanliness class).
2
Display of the measured flow rate (50 ml/min is recommended).
3
Indicates elapsed measuring time in %. Starts at 0%, at 100% a new display of the
the cleanliness class starts.
4
Display of actual cleanliness class as ISO code (>4µm
The "trend arrow" indicates very small changes:
(­: increasing contamination, ¯: decreasing contamination). It indicates changes
which would not otherwise be obvious from the class indication alone.
Using the keys :
and the display of particle quantity.
5
When displaying particle quantity, by using the keys:
between differential (particle sizes: 4- 6µm
68µm
(c)
>14µm
The chosen format is indicated with a "D" (differential) or "C" (cumulative) after the
display of the elapsed measuring time.
HYDAC Filtertechnik GmbH
M1 68%
Q: 50ml
18/15/12
3
M1 86%C
4µm:
Q: 50ml
6µm:
5
ISO
Partikel
and >68µm
) and cumulative display (particle sizes: >4µm
(c)
, >21µm
, >38µm
(c)
(c)
(c)
ISO
24671
3567
, you can switch between displaying in ISO coding
, 6-14µm
(c)
and >68µm
).
(c)
E
Doc.: 3109776 Ed.: 01/13.02.2002
4
/ >6µm
/ >14µm
(c)
(c)
, you can choose
, 14-21µm
, 21-38µm
(c)
(c)
, >6µm
(c)
)
(c)
, 38-
(c)
,
(c)
Page 91