Setting The Pressure Switch - EINHELL EURO 1500/1 Mode D'emploi

Masquer les pouces Voir aussi pour EURO 1500/1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Anleitung Euro 1500-1 SPK1
Regular oil level checks
5
Important! It is imperative to
check the oil level after every
10 hours of operation.
The level of oil has to be visible
in the sight-glass between the
red check-point mark and the
upper edge of the sight-glass.
Changing the oil:
Recommended grade SAE
15W/40 or equivalent.
The first oil change should be
carried out after 100 operating
Cleaning the intake filter
hours. Thereafter you should
The intake filter prevents dust
drain the oil and replace it with
and dirt being drawn into the
new oil at intervals of 500
machine. This filter has to be
operating hours.
cleaned at intervals of no
longer than 300 operating
Changing the oil
hours. A clogged intake filter
Switch off the motor and pull
has a considerable negative
the power plug out of the
effect on the compressor's
socket-outlet. After letting off
power.
any air pressure you can
The filter can be removed as
remove the oil drain plug from
shown in Figure 5. Wash out
the compressor pump by un-
the filter with petroleum ether
screwing. To prevent the oil
and reinsert.
escaping out of control, hold a
Caution! Wait until the
small piece of metal guttering
compressor has cooled
underneath the drain plug to
completely!
direct the oil into a container.
Risk of burns!
If any oil still remains inside, tilt
the compressor a little.
Setting the pressure
Take the old oil to an official
switch
old oil disposal station.
The pressure switch is set at the
When the old oil has run out,
factory.
screw the oil drain plug/sight-
glass back in place.
Switch-on pressure 5 bar
Switch-off pressure 8 bar
Use a screwdriver to remove
the cap of the oil filler plug and
Possible causes of
fill in oil until the level of oil in
machine failure
the sight-glass reaches the red
mark.
Overloading of the motor and
Then put the cap back on the
hence triggering of the overload
oil filler plug.
circuit-breaker may result from:
An excessively high mains
1 Filter
voltage
2 Oil filler plug
Excessively high ambient
3 Oil drain plug / sight-glass
temperatures and an
insufficient air supply
Defective compressor valves or
a leaking non-return valve
A low level of oil, sluggish
05.07.2005
8:54 Uhr
Seite 11
connecting rod bearings
Leave a.c. motors enough time to
cool off before switching on again.
Avoid touching hot components
and pipe lines.
Ordering replacement
parts
Please quote the following data
when ordering replacement parts:
Type of machine
Article number of the machine
Identification number of the
machine
Replacement part number of
the part required
For our latest prices and
information please go to www.isc-
gmbh.info
GB
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

40.100.50

Table des Matières