Brief description of the press device (Fig.1)

The ACO403 BT press device comprises the press device (8) and a fixed adaptor jaw (9). The head
with the adaptor jaw can be rotated through 180°. It is only possible to adjust the head before the
pressing operation. The head cannot be rotated while the pressing operation is being performed.
To carry out the pressing operation, hold the device tightly on handle (6) and on grip (7) on the
adaptor jaw.
7.1 Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing operation is completed
every time. For safety reasons, the automatic press cycle only switches on when the pressing
operation has started, i.e. from when the fitting starts to be shaped.
After the automatic press cycle has been triggered, the green LED (2) goes out and the pressing
operation runs automatically. The pressing operation can then only be stopped by pressing and
holding release button (5). After the pressing operation has been completed, the motor automatically
switches off and the green LED (2) lights up again.
If start button (1) is released before the automatic press cycle begins, the piston in the press device
moves back to its starting position. The pressing operation will not have been completed. The pressing
operation must be triggered again.
7.2 Release button (Fig. 1)
In the event of an emergency, the pressing operation can be stopped at any time by pressing and
holding release button (5). The piston in the press device then returns to its starting position.
7.3 Wireless interface (Fig. 1)
The device ACO403 BT features a wireless interface.
This wireless interface together with the NovoCheck app can be used to connect the ACO403 BT to a
mobile terminal device, such as a smartphone, tablet, etc. (Android, IOS; further information at
www.novopress.de). The following functions are available:
Reading the press device
Checking the press device
Making settings
Generating construction site reports.
To establish a connection, the press device must be operational and the NovoCheck app installed on
the terminal device.
The press device can now be connected with the NovoCheck app. (For more information, go to
www.novopress.de) When the connection to the wireless interface was established successfully, the
blue LED (10) lights up.
The blue LED (10) goes out if no connection has been established until the first pressing operation is
performed. A new attempt to establish the connection can only be made if the press device has been
switched off in the meantime. It may be necessary to pull the rechargeable battery for this.
If you do not wish to establish a connection, press the start button (1) once again and perform the
pressing operation.
7.4 Battery
Removing the battery (Fig. 2)
Push in (1) the two release buttons (A) and then remove the battery (2).
Inserting the battery (Fig. 3)
Slide the battery into the device as illustrated until it clicks into place.