8.
In order to start the process, press the start button and hold it down.
9.
After the pressing operation has been completed, open the adaptor jaw using the grip and detach
it from the press collar.
10. Open the press collar and remove it.

10 Re-pressing

Re-pressing is always necessary if a pressing operation has not been fully completed. Check the
system supplier's instructions to ascertain whether re-pressing is permitted. If it is permitted, please
note the following differences from the initial pressing operation that must be complied with.
WARNING!
Risk of injury from breaking claws on the adaptor jaw and damaged pins
on the press collar
Holding the press device incorrectly and changing its position before and during re-
pressing means that the claws can no longer grip the pins properly.
The tips of the claws may press directly on the pins, causing the claws and pins to
break and fragments to fly off.
Therefore:

11 Cleaning, maintenance and repair

CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing
the On switch.
Therefore:

Service addresses

Novopress GmbH Pressen und Presswerkzeuge & Co. KG
Welserstr. 7
41468 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
After positioning on the press collar, press the jaw levers on the adaptor jaw
together as far as possible using the grip. (Fig. 14)
Make sure that the claws of the adaptor jaw always grip the press collar pins
throughout the re-pressing operation and that the markings (L) on the claws (21)
are fully covered. (Fig. 11 + 12)
Comply with the safety instructions and always remove the battery before
performing cleaning, servicing or repair work.