NovoPress ACO403 BT Manuel D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
ACO403 BT
EN
1.
Check that the nominal size of the press fitting matches the nominal size of the press collar.
2.
Swivel the outer shells of the press collar outwards as far as possible and then position the press
collar on the press fitting.
3.
Close the press collar. (Fig. 6)
4.
Open the adaptor jaw fully using the grip (7).
5.
Position the adaptor jaw on the press collar as follows.
Push claws (21) of the adaptor jaw as far as possible into grooves (24) in the press collar.
(Fig. 10)
6.
Close the adaptor jaw using the grip (7).
7.
Check that the markings (L/Fig. 12) on the claws (21) of the adaptor jaw are fully covered.
If a marking is partially visible, the adaptor jaw must be placed again.
Information!
To ensure that the press collars function correctly, the sliding segments must be free to
move.
The sliding segments are always pressed back automatically into the correct starting
position by springs.
Therefore:
Ensure that marking lines (M) on shells (C) are aligned with the edges of the sliding
segments (D) when the press collar is in starting position. (Fig. 5)
If this is not the case, have the press collars repaired.
Information!
Comply with the system supplier's instructions when positioning the press collar on the
press fitting.
CAUTION!
There is a risk that the press collar will break if it is positioned incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore:
The line (A) must be at the same height of the edge (B).
If this is not the case, remove the press collar again and reposition it
WARNING!
Risk of injury from ejected fragments
If the adaptor jaw is positioned on the press collar incorrectly, the adaptor jaw and the
press collar may break.
Therefore
Claws (21) of the adaptor jaw must grip pins (22) of the press collar.
(Fig. 11, 12 + 13)
The markings (L/Fig. 11 + 12) on the claws (21) of the adaptor jaw must be fully
covered when the press collar has been placed (Fig. 11+ 12)..
Information!
Ensure there is no gap between the segments of the press collar when the
pressing operation is complete.
Information!
If the press device is switched off, briefly press the start button (1) to activate the
press device. Press the start button again to start the pressing operation.
24
(Fig. 7)

Publicité

Table des Matières
loading

Table des Matières