9 - Open commands
AUXLIARY FUNCTION
WHO
9
Example:
To switch ON the heater on AUX = 2, the Open Web Net code is:
WHO
WHAT = 1 ON.
WHERE = 2 AUX channel 2.
162
WHAT
Function
OFF
ON
TOGGLE
STOP
UP
DOWN
ENABLE
DISABLE
GEN. RESET
BI RESET
TRI RESET
= 9 auxiliaries.
The AUXILIARY CHANNEL number can be obtained from the burglar-alarm diagram; it
shall be identical to the number of the confi gurator placed in the AUX housing of the
actuator relay connected to the device (see actuator relay instructions sheet of the SCS
anti-intrusion system).
WHERE
Value
Function
0
AUX channel0
1
AUX channel1
2
AUX channel2
3
AUX channel3
4
AUX channel4
5
AUX channel5
6
AUX channel6
7
AUX channel7
8
AUX channel8
9
AUX channel9
10
*9*1*2##
Value
0
1
2
3
4
5
6
7
8
9