9 - Open commands
FREE TIMING
This command can activate the switching on of a light for a time which the user can define as
required; the timing limit is 255 hours, 59 minutes and 59 seconds. This function can also be
programmed using the SecurityConfig software.
Example:
To switch on Z=2 N=4 light point for 12 hours, 5 minutes, 0 seconds type the following
command:
AUTOMATION FUNCTION
WHO
2
Example:
To roll down the room roller shutters (group 4) the Open Web Net code is: *2*2*#4*##
WHO = 2 control unit, WHAT = 2 DOWN, WHERE = #4 group 4.
QUERYING THE SYSTEM
to know the status of the N device in the Z, room, the code is the following:
154
*#1*ZN*#2*ORE*MINUTES*SECONDS##
WHAT
Function
STOP
UP
DOWN
*#1*24*#2*12*5*0##
WHERE
Value
Function
0
General
1
Room 1
2
Room ...
Room 9
Light point 11
Light point ...
Light point 99
Group 1
Group ...
Group 9
*#2*ZN##
WHEN
Value
Function
0
Not used in
this function
1
...
9
11
...
99
#1
...
#9
Value

Publicité