Carel k.Air large Manuel D'utilisation page 154

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FRE
Variable
PreHeatPmp_1.Val_W
PreHeatPmp_1.Enable_W
PreHeatPmp_1.Confi gured_R
PreHeatPmp_2.Val_Hw_R
PreHeatPmp_2.Val_W
PreHeatPmp_2.Enable_W
PreHeatPmp_2.Confi gured_R
MainCoilPmp_1.Val_Hw_R
MainCoilPmp_1.Val_W
MainCoilPmp_1.Enable_W
MainCoilPmp_1.Confi gured_R
MainCoilPmp_2.Val_Hw_R
MainCoilPmp_2.Val_W
MainCoilPmp_2.Enable_W
MainCoilPmp_2.Confi gured_R
ReHeatPmp_1.Val_Hw_R
ReHeatPmp_1.Val_W
ReHeatPmp_1.Enable_W
ReHeatPmp_1.Confi gured_R
ReHeatPmp_2.Val_Hw_R
ReHeatPmp_2.Val_W
ReHeatPmp_2.Enable_W
ReHeatPmp_2.Confi gured_R
FreshAirPreHeatPmp_1.Val_Hw_R
FreshAirPreHeatPmp_1.Val_W
FreshAirPreHeatPmp_1.Enable_W
FreshAirPreHeatPmp_1.Confi gured_R
FreshAirPreHeatPmp_2.Val_Hw_R
FreshAirPreHeatPmp_2.Val_W
FreshAirPreHeatPmp_2.Enable_W
FreshAirPreHeatPmp_2.Confi gured_R
FiltAlrm_Dout.Val_Hw_R
FiltAlrm_Dout.Val_W
FiltAlrm_Dout.Enable_W
FiltAlrm_Dout.Confi gured_R
Recovery_Dout.Val_Hw_R
Recovery_Dout.Val_W
Recovery_Dout.Enable_W
Recovery_Dout.Confi gured_R
IEC_Hum_Dout.Val_Hw_R
IEC_Hum_Dout.Val_W
IEC_Hum_Dout.Enable_W
IEC_Hum_Dout.Confi gured_R
SupplyFan_Aout.Enable_W
SupplyFan_Aout.Confi gured_R
RetFan_Aout.Enable_W
RetFan_Aout.Confi gured_R
BypassDamp_Aout.Enable_W
BypassDamp_Aout.Confi gured_R
MixingDamp_Aout.Enable_W
MixingDamp_Aout.Confi gured_R
FreshAirDamp_Aout.Enable_W
FreshAirDamp_Aout.Confi gured_R
ReHeatCoil_Aout.Enable_W
ReHeatCoil_Aout.Confi gured_R
PreHeatCoil_Aout.Enable_W
PreHeatCoil_Aout.Confi gured_R
FreshAirPreHeatCoil_Aout.Enable_W
FreshAirPreHeatCoil_Aout.Confi gured_R
MainCoil_Aout.Enable_W
MainCoil_Aout.Confi gured_R
ThrmlWheel_Aout.Enable_W
ThrmlWheel_Aout.Confi gured_R
154
Tableau des variables de supervision
Description
Pre-Heating pump 1
Pre-Heating pump 1 - Enable output
Pre-Heating pump 1 - Output confi gurated
Pre-Heating pump 2 - Hardware value writes from board
Pre-Heating pump 2
Pre-Heating pump 2 - Enable output
Pre-Heating pump 2 - Output confi gurated
Main pump 1 - Hardware value writes from board
Main pump 1
Main pump 1 - Enable output
Main pump 1 - Output confi gurated
Main pump 2 - Hardware value writes from board
Main pump 2
Main pump 2 - Enable output
Main pump 2 - Output confi gurated
Re-Heating pump 1 - Hardware value writes from board
Re-Heating pump 1
Re-Heating pump 1 - Enable output
Re-Heating pump 1 - Output confi gurated
Re-Heating pump 2 - Hardware value writes from board
Re-Heating pump 2
Re-Heating pump 2 - Enable output
Re-Heating pump 2 - Output confi gurated
Fresh Air pre-Heating pump 1 - Hardware value writes from board 1
Fresh Air pre-Heating pump 1
Fresh Air pre-Heating pump 1 - Enable output
Fresh Air pre-Heating pump 1 - Output confi gurated
Fresh Air pre-Heating pump 2 - Hardware value writes from board 1
Fresh Air pre-Heating pump 2
Fresh Air pre-Heating pump 2 - Enable output
Fresh Air pre-Heating pump 2 - Output confi gurated
Filters alarm - Hardware value writes from board
Filters alarm
Filters alarm - Enable output
Filters alarm - Output confi gurated
Recovery - Hardware value writes from board
Recovery
Recovery - Enable output
Recovery - Output confi gurated
IEC humidifer - Hardware value writes from board
IEC humidifer
IEC humidifer - Enable output
IEC humidifer - Output confi gurated
Supply fan - Enable output
Supply fan - Analog output confi gured
Return fan - Enable output
Return fan - Analog output confi gured
Bypass damper - Enable output
Bypass damper - Analog output confi gured
Mixing damper - Enable output
Mixing damper - Analog output confi gured
Fresh air damper - Enable output
Fresh air damper - Analog output confi gured
Reheat heater - Enable output
Reheat heater - Analog output confi gured
Pre-Heating heater - Enable output
Pre-Heating heater - Analog output confi gured
Fresh air pre-heating heater - Enable output
Fresh air pre-heating heater - Analog output confi gured
Main coil valve - Enable output
Main coil valve - Analog output confi gured
Thermal wheel - Enable output
Thermal wheel - Analog output confi gured
Dim Modbus
BACnet
1
DI564
BV1022
1
DI565
BV1023
1
DI566
BV1024
1
DI567
BV1025
1
DI568
BV1026
1
DI569
BV1027
1
DI570
BV1028
1
DI571
BV1029
1
DI572
BV1030
1
DI573
BV1031
1
DI574
BV1032
1
DI575
BV1033
1
DI576
BV1034
1
DI577
BV1035
1
DI578
BV1036
1
DI579
BV1037
1
DI580
BV1038
1
DI581
BV1039
1
DI582
BV1040
1
DI583
BV1041
1
DI584
BV1042
1
DI585
BV1043
1
DI586
BV1044
DI587
BV1045
1
DI588
BV1046
1
DI589
BV1047
1
DI590
BV1048
DI591
BV1049
1
DI592
BV1050
1
DI593
BV1051
1
DI594
BV1052
1
DI595
BV1053
1
DI596
BV1054
1
DI597
BV1055
1
DI598
BV1056
1
DI599
BV1057
1
DI600
BV1058
1
DI601
BV1059
1
DI602
BV1060
1
DI603
BV1061
1
DI604
BV1062
1
DI605
BV1063
1
DI606
BV1064
1
DI607
BV1065
1
DI608
BV1066
1
DI609
BV1067
1
DI610
BV1068
1
DI611
BV1069
1
DI612
BV1070
1
DI613
BV1071
1
DI614
BV1072
1
DI615
BV1073
1
DI616
BV1074
1
DI617
BV1075
1
DI618
BV1076
1
DI619
BV1077
1
DI620
BV1078
1
DI621
BV1079
1
DI622
BV1080
1
DI623
BV1081
1
DI624
BV1082
1
DI625
BV1083
1
DI626
BV1084
k.air +030220982 rel 1.1 - 31.03.2020