Carel k.Air large Manuel D'utilisation page 167

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Variable
FreshAirPreHeatCoilFlwSw.Board_RW
FreshAirPreHeatCoilFlwSw.Ch_Id_RW
RecoveryClogged.Board_RW
RecoveryClogged.Ch_Id_RW
ReHeatAlrm.Board_RW
ReHeatAlrm.Ch_Id_RW
PreHeatAlrm.Board_RW
PreHeatAlrm.Ch_Id_RW
MainHeatCoilAlrm.Board_RW
MainHeatCoilAlrm.Ch_Id_RW
FreshAirPreHeatAlrm.Board_RW
FreshAirPreHeatAlrm.Ch_Id_RW
DoorSw.Board_RW
DoorSw.Ch_Id_RW
FireSmokeAlrm.Board_RW
FireSmokeAlrm.Ch_Id_RW
FiremanOverrideSw.Board_RW
FiremanOverrideSw.Ch_Id_RW
CoolHeatModeByDin.Board_RW
CoolHeatModeByDin.Ch_Id_RW
Din_SetP.Board_RW
Din_SetP.Ch_Id_RW
Eco_Mode.Board_RW
Eco_Mode.Ch_Id_RW
PreComf_Mode.Board_RW
PreComf_Mode.Ch_Id_RW
Comf_Mode.Board_RW
Comf_Mode.Ch_Id_RW
AuxDin_1.Board_RW
AuxDin_1.Ch_Id_RW
AuxDin_2.Board_RW
AuxDin_2.Ch_Id_RW
AuxDin_3.Board_RW
AuxDin_3.Ch_Id_RW
AuxDin_4.Board_RW
AuxDin_4.Ch_Id_RW
DfrHeatExch_Din.Board_RW
DfrHeatExch_Din.Ch_Id_RW
BypassDamp_Dout.Board_RW
BypassDamp_Dout.Ch_Id_RW
BypassDamp_Dout.T_On_RW
BypassDamp_Dout.T_Off _RW
BypassDamp_Dout.Ch_Type_RW
BypassDamp_Open.Board_RW
BypassDamp_Open.Ch_Id_RW
BypassDamp_Open.T_On_RW
BypassDamp_Open.T_Off _RW
BypassDamp_Open.Ch_Type_RW
BypassDamp_Close.Board_RW
BypassDamp_Close.Ch_Id_RW
BypassDamp_Close.T_On_RW
BypassDamp_Close.T_Off _RW
BypassDamp_Close.Ch_Type_RW
FreshAirDamp_Dout.Board_RW
FreshAirDamp_Dout.Ch_Id_RW
FreshAirDamp_Dout.T_On_RW
FreshAirDamp_Dout.T_Off _RW
FreshAirDamp_Dout.Ch_Type_RW
ExhAirDamp_Dout.Board_RW
ExhAirDamp_Dout.Ch_Id_RW
ExhAirDamp_Dout.T_On_RW
ExhAirDamp_Dout.T_Off _RW
ExhAirDamp_Dout.Ch_Type_RW
k.air +030220982 rel 1.1 - 31.03.2020
Description
Fresh Air Pre-Heaing coil fl ow switch - Board selected
Fresh Air Pre-Heaing coil fl ow switch - Channel id selected
Recovery clogged - Board selected
Recovery clogged - Channel id selected
Re-heating alarm - Board selected
Re-heating alarm - Channel id selected
Pre-heating alarm - Board selected
Pre-heating alarm - Channel id selected
Main coil alarm - Board selected
Main coil alarm - Channel id selected
Fresh Air Pre-Heat alarm - Board selected
Fresh Air Pre-Heat alarm - Channel id selected
Door Switch - Board selected
Door Switch - Channel id selected
Fire/Smoke alarm - Board selected
Fire/Smoke alarm - Channel id selected
Fireman override switch - Board selected
Fireman override switch - Channel id selected
CoolHeatModeByDin - Board selected
CoolHeatModeByDin - Channel id selected
Setpoint by digital input - Board selected
Setpoint by digital input - Channel id selected
Eco mode - Board selected
Eco mode - Channel id selected
Precomfort mode - Board selected
Precomfort mode - Channel id selected
Comfort mode - Board selected
Comfort mode - Channel id selected
Auxiliary digital input 1 - Board selected
Auxiliary digital input 1 - Channel id selected
Auxiliary digital input 2 - Board selected
Auxiliary digital input 2 - Channel id selected
Auxiliary digital input 3 - Board selected
Auxiliary digital input 3 - Channel id selected
Auxiliary digital input 4 - Board selected
Auxiliary digital input 4 - Channel id selected
Heat exchanger defrost by Din - Board selected
Heat exchanger defrost by Din - Channel id selected
Bypass damper - Board selected
Bypass damper - Channel id selected
Bypass damper - Time on cycle relay
Bypass damper - Time off cycle releay
Bypass damper - Digital output type
Bypass damper fl oating (open) - Board selected
Bypass damper fl oating (open) - Channel id selected
Bypass damper fl oating (open) - Time on cycle relay
Bypass damper fl oating (open) - Time off cycle releay
Bypass damper fl oating (open) - Digital output type
Bypass damper fl oating (close) - Board selected
Bypass damper fl oating (close) - Channel id selected
Bypass damper fl oating (close) - Time on cycle relay
Bypass damper fl oating (close) - Time off cycle releay
Bypass damper fl oating (close) - Digital output type
Fresh air damper - Board selected
Fresh air damper - Channel id selected
Fresh air damper - Time on cycle relay
Fresh air damper - Time off cycle releay
Fresh air damper - Digital output type
Exhaust air damper - Board selected
Exhaust air damper - Channel id selected
Exhaust air damper - Time on cycle relay
Exhaust air damper - Time off cycle releay
Exhaust air damper - Digital output type
Dim Modbus
1
HR514
1
HR515
1
HR516
1
HR517
1
HR518
1
HR519
1
HR520
1
HR521
1
HR522
1
HR523
1
HR524
1
HR525
1
HR526
1
HR527
1
HR528
1
HR529
1
HR530
1
HR531
1
HR532
1
HR533
1
HR534
1
HR535
1
HR536
1
HR537
1
HR538
1
HR539
1
HR540
1
HR541
1
HR542
1
HR543
1
HR544
1
HR545
1
HR546
1
HR547
1
HR548
1
HR549
1
HR550
1
HR551
1
HR552
1
HR553
1
HR554
1
HR555
1
HR556
1
HR557
1
HR558
1
HR559
1
HR560
1
HR561
1
HR562
1
HR563
1
HR564
1
HR565
1
HR566
1
HR567
1
HR568
1
HR569
1
HR570
1
HR571
1
HR572
1
HR573
1
HR574
1
HR575
1
HR576
Tableau des variables de supervision
FRE
BACnet
PIV2037
PIV2038
PIV2039
PIV2040
PIV2041
PIV2042
PIV2043
PIV2044
PIV2045
PIV2046
PIV2047
PIV2048
PIV2049
PIV2050
PIV2051
PIV2052
PIV2053
PIV2054
PIV2055
PIV2056
PIV2057
PIV2058
PIV2059
PIV2060
PIV2061
PIV2062
PIV2063
PIV2064
PIV2065
PIV2066
PIV2067
PIV2068
PIV2069
PIV2070
PIV2071
PIV2072
PIV2073
PIV2074
PIV2075
PIV2076
PIV2077
PIV2078
PIV2079
PIV2080
PIV2081
PIV2082
PIV2083
PIV2084
PIV2085
PIV2086
PIV2087
PIV2088
PIV2089
PIV2090
PIV2091
PIV2092
PIV2093
PIV2094
PIV2095
PIV2096
PIV2097
PIV2098
PIV2099
167

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K.air miniC.pcoeK.air

Table des Matières