Carel k.Air large Manuel D'utilisation page 149

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Variable
MainCoilPmp1_Ovld.Confi gured_R
MainCoilPmp1_Ovld.Val_R
MainCoilPmp2_Ovld.Val_Hw_R
MainCoilPmp2_Ovld.Enable_W
MainCoilPmp2_Ovld.Confi gured_R
MainCoilPmp2_Ovld.Val_R
ReHeatCoilPmp1_Ovld.Val_Hw_R
ReHeatCoilPmp1_Ovld.Enable_W
ReHeatCoilPmp1_Ovld.Confi gured_R
ReHeatCoilPmp1_Ovld.Val_R
ReHeatCoilPmp2_Ovld.Val_Hw_R
ReHeatCoilPmp2_Ovld.Enable_W
ReHeatCoilPmp2_Ovld.Confi gured_R
ReHeatCoilPmp2_Ovld.Val_R
PreHeatCoilPmp1_Ovld.Val_Hw_R
PreHeatCoilPmp1_Ovld.Enable_W
PreHeatCoilPmp1_Ovld.Confi gured_R
PreHeatCoilPmp1_Ovld.Val_R
PreHeatCoilPmp2_Ovld.Val_Hw_R
PreHeatCoilPmp2_Ovld.Enable_W
PreHeatCoilPmp2_Ovld.Confi gured_R
PreHeatCoilPmp2_Ovld.Val_R
FreshAirPreHeatCoilPmp1_ Ovld.Val_ Hw_R
FreshAirPreHeatCoilPmp1_ Ovld.Enable_W
FreshAirPreHeatCoilPmp1_Ovld.Confi gured_R
FreshAirPreHeatCoilPmp1_Ovld.Val_R
FreshAirPreHeatCoilPmp2_ Ovld.Val_ Hw_R
FreshAirPreHeatCoilPmp2_ Ovld.Enable_W
FreshAirPreHeatCoilPmp2_Ovld.Confi gured_R
FreshAirPreHeatCoilPmp2_Ovld.Val_R
FreshAirDampSw.Val_Hw_R
FreshAirDampSw.Enable_W
FreshAirDampSw.Confi gured_R
FreshAirDampSw.Val_R
SupplyDamperSw.Val_Hw_R
SupplyDamperSw.Enable_W
SupplyDamperSw.Confi gured_R
SupplyDamperSw.Val_R
RetDampSw.Val_Hw_R
RetDampSw.Enable_W
RetDampSw.Confi gured_R
RetDampSw.Val_R
MainCoilFlwSw.Val_Hw_R
MainCoilFlwSw.Enable_W
MainCoilFlwSw.Confi gured_R
MainCoilFlwSw.Val_R
PreHeatCoilFlwSw.Val_Hw_R
PreHeatCoilFlwSw.Enable_W
PreHeatCoilFlwSw.Confi gured_R
PreHeatCoilFlwSw.Val_R
ReHeatCoilFlwSw.Val_Hw_R
ReHeatCoilFlwSw.Enable_W
ReHeatCoilFlwSw.Confi gured_R
ReHeatCoilFlwSw.Val_R
FreshAirPreHeatCoilFlwSw.Val_Hw_R
FreshAirPreHeatCoilFlwSw.Enable_W
FreshAirPreHeatCoilFlwSw.Confi gured_R
FreshAirPreHeatCoilFlwSw.Val_R
RecoveryClogged.Val_Hw_R
RecoveryClogged.Enable_W
RecoveryClogged.Confi gured_R
RecoveryClogged.Val_R
ReHeatAlrm.Val_Hw_R
k.air +030220982 rel 1.1 - 31.03.2020
Description
Main coil pump 1 overload - Digital input confi gured
Main coil pump 1 overload
Main coil pump 2 overload - Value reads from board
Main coil pump 2 overload - Enable input
Main coil pump 2 overload - Digital input confi gured
Main coil pump 2 overload
ReHeat coil pump 1 overload - Value reads from board
ReHeat coil pump 1 overload - Enable input
ReHeat coil pump 1 overload - Digital input confi gured
ReHeat coil pump 1 overload
ReHeat coil pump 2 overload - Value reads from board
ReHeat coil pump 2 overload - Enable input
ReHeat coil pump 2 overload - Digital input confi gured
ReHeat coil pump 2 overload
PreHeat coil pump 1 overload - Value reads from board
PreHeat coil pump 1 overload - Enable input
PreHeat coil pump 1 overload - Digital input confi gured
PreHeat coil pump 1 overload
PreHeat coil pump 2 overload - Value reads from board
PreHeat coil pump 2 overload - Enable input
PreHeat coil pump 2 overload - Digital input confi gured
PreHeat coil pump 2 overload
Fresh air preHeat coil pump 1 overload - Value reads from board 1
Fresh air preHeat coil pump 1 overload - Enable input
Fresh air preHeat coil pump 1 overload - Digital input confi gured 1
Fresh air preHeat coil pump 1 overload
Fresh air preHeat coil pump 2 overload - Value reads from board 1
Fresh air preHeat coil pump 2 overload - Enable input
Fresh air preHeat coil pump 2 overload - Digital input confi gured 1
Fresh air preHeat coil pump 2 overload
Fresh air damper switch - Value reads from board
Fresh air damper switch - Enable input
Fresh air damper switch - Digital input confi gured
Fresh air damper switch
Supply damper switch - Value reads from board
Supply damper switch - Enable input
Supply damper switch - Digital input confi gured
Supply damper switch
Return damper switch - Value reads from board
Return damper switch - Enable input
Return damper switch - Digital input confi gured
Return damper switch
Main coil fl ow switch - Value reads from board
Main coil fl ow switch - Enable input
Main coil fl ow switch - Digital input confi gured
Main coil fl ow switch
Pre-heating coil fl ow switch - Value reads from board
Pre-heating coil fl ow switch - Enable input
Pre-heating coil fl ow switch - Digital input confi gured
Pre-heating coil fl ow switch
Post-Heating coil fl ow switch - Value reads from board
Post-Heating coil fl ow switch - Enable input
Post-Heating coil fl ow switch - Digital input confi gured
Post-Heating coil fl ow switch
Fresh Air Pre-Heaing coil fl ow switch - Value reads from board 1
Fresh Air Pre-Heaing coil fl ow switch - Enable input
Fresh Air Pre-Heaing coil fl ow switch - Digital input confi gured
Fresh Air Pre-Heaing coil fl ow switch
Recovery clogged - Value reads from board
Recovery clogged - Enable input
Recovery clogged - Digital input confi gured
Recovery clogged
Re-heating alarm - Value reads from board
Dim Modbus
1
DI241
1
DI242
1
DI243
1
DI244
1
DI245
1
DI246
1
DI247
1
DI248
1
DI249
1
DI250
1
DI251
1
DI252
1
DI253
1
DI254
1
DI255
1
DI256
1
DI257
1
DI258
1
DI259
1
DI260
1
DI261
1
DI262
DI263
1
DI264
DI265
1
DI266
DI267
1
DI268
DI269
1
DI270
1
DI271
1
DI272
1
DI273
1
DI274
1
DI275
1
DI276
1
DI277
1
DI278
1
DI279
1
DI280
1
DI281
1
DI282
1
DI283
1
DI284
1
DI285
1
DI286
1
DI287
1
DI288
1
DI289
1
DI290
1
DI291
1
DI292
1
DI293
1
DI294
DI295
1
DI296
1
DI297
1
DI298
1
DI299
1
DI300
1
DI301
1
DI302
1
DI303
Tableau des variables de supervision
FRE
BACnet
BV699
BV700
BV701
BV702
BV703
BV704
BV705
BV706
BV707
BV708
BV709
BV710
BV711
BV712
BV713
BV714
BV715
BV716
BV717
BV718
BV719
BV720
BV721
BV722
BV723
BV724
BV725
BV726
BV727
BV728
BV729
BV730
BV731
BV732
BV733
BV734
BV735
BV736
BV737
BV738
BV739
BV740
BV741
BV742
BV743
BV744
BV745
BV746
BV747
BV748
BV749
BV750
BV751
BV752
BV753
BV754
BV755
BV756
BV757
BV758
BV759
BV760
BV761
149

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K.air miniC.pcoeK.air

Table des Matières