Carel k.Air large Manuel D'utilisation page 151

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Variable
DfrHeatExch_Din.Val_Hw_R
DfrHeatExch_Din.Enable_W
DfrHeatExch_Din.Confi gured_R
DfrHeatExch_Din.Val_R
BypassDamp_Dout.Val_W
BypassDamp_Dout.Enable_W
BypassDamp_Dout.Confi gured_R
BypassDamp_Open.Val_Hw_R
BypassDamp_Open.Val_W
BypassDamp_Open.Enable_W
BypassDamp_Open.Confi gured_R
BypassDamp_Close.Val_Hw_R
BypassDamp_Close.Val_W
BypassDamp_Close.Enable_W
BypassDamp_Close.Confi gured_R
FreshAirDamp_Dout.Val_Hw_R
FreshAirDamp_Dout.Enable_W
FreshAirDamp_Dout.Confi gured_R
ExhAirDamp_Dout.Val_W
ExhAirDamp_Dout.Enable_W
ExhAirDamp_Dout.Confi gured_R
MixingDamp_Dout.Val_W
MixingDamp_Dout.Enable_W
MixingDamp_Dout.Confi gured_R
SupplyAirDamp_Dout.Val_Hw_R
SupplyAirDamp_Dout.Val_W
SupplyAirDamp_Dout.Enable_W
SupplyAirDamp_Dout.Confi gured_R
RetAirDamp_Dout.Val_Hw_R
RetAirDamp_Dout.Val_W
RetAirDamp_Dout.Enable_W
RetAirDamp_Dout.Confi gured_R
MixingDamp_Open.Val_Hw_R
MixingDamp_Open.Val_W
MixingDamp_Open.Enable_W
MixingDamp_Open.Confi gured_R
MixingDamp_Close.Val_Hw_R
MixingDamp_Close.Val_W
MixingDamp_Close.Enable_W
MixingDamp_Close.Confi gured_R
SupplyFan_Dout.Val_W
SupplyFan_Dout.Enable_W
SupplyFan_Dout.Confi gured_R
RetFan_Dout.Val_W
RetFan_Dout.Enable_W
RetFan_Dout.Confi gured_R
SupplyFan2_Dout.Val_Hw_R
SupplyFan2_Dout.Val_W
SupplyFan2_Dout.Enable_W
SupplyFan2_Dout.Confi gured_R
RetFan2_Dout.Val_Hw_R
RetFan2_Dout.Val_W
RetFan2_Dout.Enable_W
RetFan2_Dout.Confi gured_R
Comp_Dout.Val_W
Comp_Dout.Enable_W
Comp_Dout.Confi gured_R
RevVlv.Val_Hw_R
RevVlv.Val_W
RevVlv.Enable_W
RevVlv.Confi gured_R
UnitOnOff _Dout.Val_Hw_R
k.air +030220982 rel 1.1 - 31.03.2020
Description
Heat exchanger defrost by Din - Value reads from board
Heat exchanger defrost by Din - Enable input
Heat exchanger defrost by Din - Digital input confi gured
Heat exchanger defrost by Din
Bypass damper
Bypass damper - Enable output
Bypass damper - Output confi gurated
Bypass damper fl oating (open) - Hardware value writes from board 1
Bypass damper fl oating (open)
Bypass damper fl oating (open) - Enable output
Bypass damper fl oating (open) - Output confi gurated
Bypass damper fl oating (close) - Hardware value writes from board 1
Bypass damper fl oating (close)
Bypass damper fl oating (close) - Enable output
Bypass damper fl oating (close) - Output confi gurated
Fresh air damper - Hardware value writes from board
Fresh air damper - Enable output
Fresh air damper - Output confi gurated
Exhaust air damper
Exhaust air damper - Enable output
Exhaust air damper - Output confi gurated
Mixing damper
Mixing damper - Enable output
Mixing damper - Output confi gurated
Supply air damper - Hardware value writes from board
Supply air damper
Supply air damper - Enable output
Supply air damper - Output confi gurated
Return air damper - Hardware value writes from board
Return air damper
Return air damper - Enable output
Return air damper - Output confi gurated
Mixing damper fl oating (OPEN) - Hardware value writes from
board
Mixing damper fl oating (OPEN)
Mixing damper fl oating (OPEN) - Enable output
Mixing damper fl oating (OPEN) - Output confi gurated
Mixing damper fl oating (CLOSE) - Hardware value writes from
board
Mixing damper fl oating (CLOSE)
Mixing damper fl oating (CLOSE) - Enable output
Mixing damper fl oating (CLOSE) - Output confi gurated
Supply fan
Supply fan - Enable output
Supply fan - Output confi gurated
Return fan
Return fan - Enable output
Return fan - Output confi gurated
Supply fan 2 - Hardware value writes from board
Supply fan 2
Supply fan 2 - Enable output
Supply fan 2 - Output confi gurated
Return fan 2 - Hardware value writes from board
Return fan 2
Return fan 2 - Enable output
Return fan 2 - Output confi gurated
Compressor
Compressor - Enable output
Compressor - Output confi gurated
Reverse valve - Hardware value writes from board
Reverse valve
Reverse valve - Enable output
Reverse valve - Output confi gurated
Unit status (On/Off ) - Hardware value writes from board
Dim Modbus
1
DI367
1
DI368
1
DI369
1
DI370
1
DI372
1
DI373
1
DI374
DI375
1
DI376
1
DI377
1
DI378
DI379
1
DI380
1
DI381
1
DI382
1
DI383
1
DI385
1
DI386
1
DI388
1
DI389
1
DI390
1
DI392
1
DI393
1
DI394
1
DI395
1
DI396
1
DI397
1
DI398
1
DI399
1
DI400
1
DI401
1
DI402
1
DI403
1
DI404
1
DI405
1
DI406
1
DI407
1
DI408
1
DI409
1
DI410
1
DI412
1
DI413
1
DI414
1
DI416
1
DI417
1
DI418
1
DI419
1
DI420
1
DI421
1
DI422
1
DI423
1
DI424
1
DI425
1
DI426
1
DI428
1
DI429
1
DI430
1
DI431
1
DI432
1
DI433
1
DI434
1
DI435
Tableau des variables de supervision
FRE
BACnet
BV825
BV826
BV827
BV828
BV830
BV831
BV832
BV833
BV834
BV835
BV836
BV837
BV838
BV839
BV840
BV841
BV843
BV844
BV846
BV847
BV848
BV850
BV851
BV852
BV853
BV854
BV855
BV856
BV857
BV858
BV859
BV860
BV861
BV862
BV863
BV864
BV865
BV866
BV867
BV868
BV870
BV871
BV872
BV874
BV875
BV876
BV877
BV878
BV879
BV880
BV881
BV882
BV883
BV884
BV886
BV887
BV888
BV889
BV890
BV891
BV892
BV893
151

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K.air miniC.pcoeK.air

Table des Matières