Variable
Al_IEC_Humifog.Active
Al_Humifog_Offl ine.Active
Al_IEC_Humifog_Offl ine.Active
Al_kwater_Offl ine.Active
Al_EEV_HWCompatErr.Active
Al_PGDx_Offl ine.Active
SupplyRecoveryTemp.Alrm_R
CoilVlv_OpenTime
Coils.PreHeatCoil_FloatVlv
Coils.ReHeatCoil_FloatVlv
MainVlv_ReadyToGo
PreHeatVlv_ReadyToGo
ReHeatVlv_ReadyToGo
RetRecoveryTemp.Enable_W
RetRecoveryTemp.Confi gured_R
RetRecoveryTemp.PrbOk_R
RetRecoveryTemp.Alrm_R
HepaFilt_1.Enable_W
HepaFilt_1.Confi gured_R
HepaFilt_1.PrbOk_R
HepaFilt_1.Alrm_R
HepaFilt_2.Enable_W
HepaFilt_2.Confi gured_R
HepaFilt_2.PrbOk_R
HepaFilt_2.Alrm_R
SupplyAirFlwSw.Val_Hw_R
SupplyAirFlwSw.Enable_W
SupplyAirFlwSw.Confi gured_R
SupplyAirFlwSw.Val_R
RetAirFlwSw.Val_Hw_R
RetAirFlwSw.Enable_W
RetAirFlwSw.Confi gured_R
RetAirFlwSw.Val_R
AirFlwSw.Val_Hw_R
AirFlwSw.Enable_W
AirFlwSw.Confi gured_R
AirFlwSw.Val_R
AFreezeSw.Val_Hw_R
AFreezeSw.Enable_W
AFreezeSw.Confi gured_R
AFreezeSw.Val_R
RemOnOff .Val_Hw_R
RemOnOff .Enable_W
RemOnOff .Confi gured_R
RemOnOff .Val_R
SupplyFanOvld_1.Val_Hw_R
SupplyFanOvld_1.Enable_W
SupplyFanOvld_1.Confi gured_R
SupplyFanOvld_1.Val_R
RetFanOvld_1.Val_Hw_R
RetFanOvld_1.Enable_W
RetFanOvld_1.Confi gured_R
RetFanOvld_1.Val_R
SupplyFanOvld_2.Val_Hw_R
SupplyFanOvld_2.Enable_W
SupplyFanOvld_2.Confi gured_R
SupplyFanOvld_2.Val_R
RetFanOvld_2.Val_Hw_R
RetFanOvld_2.Enable_W
RetFanOvld_2.Confi gured_R
k.air +030220982 rel 1.1 - 31.03.2020
Description
Alarm - IEC Humifog alarms present - Alarm status
Alarm - Humifog offl ine - Alarm status
Alarm - IEC Humifog offl ine - Alarm status
Warning - k.water offl ine - Alarm status
Alarm - EEV Hardware compatibility error - Alarm status
Warning - pGDx Offl ine - Alarm status
Supply recovery temperature - Alarm probe broken or
disconnected
Coil fl oating valve: Opening duration total time(from0% to100%) 1
PreHeat coil type: fl oating valve
ReHeat coil type: fl oating valve
Main Coil: fl oating valve ready to go( FALSE: Pre-positioning in
progress; TRUE: Valve ready)
PreHeat Coil: fl oating valve ready to go( FALSE: Pre-positio-
ning in progress; TRUE: Valve ready)
ReHeat Coil: fl oating valve ready to go( FALSE: Pre-positioning
in progress; TRUE: Valve ready)
Return recovery temperature - Enable input
Return recovery temperature - Analog input confi gured
Return recovery temperature - Probe working correctly
Return recovery temperature - Alarm probe broken or discon-
nected
Hepa fi lter 1 - Enable input
Hepa fi lter 1 - Analog input confi gured
Hepa fi lter 1 - Probe working correctly
Hepa fi lter 1 - Alarm probe broken or disconnected
Hepa fi lter 2 - Enable input
Hepa fi lter 2 - Analog input confi gured
Hepa fi lter 2 - Probe working correctly
Hepa fi lter 2 - Alarm probe broken or disconnected
Supply air fl ow switch - Value reads from board
Supply air fl ow switch - Enable input
Supply air fl ow switch - Digital input confi gured
Supply air fl ow switch
Return air fl ow switch - Value reads from board
Return air fl ow switch - Enable input
Return air fl ow switch - Digital input confi gured
Return air fl ow switch
Air fl ow switch - Value reads from board
Air fl ow switch - Enable input
Air fl ow switch - Digital input confi gured
Air fl ow switch
Antifreeze switch - Value reads from board
Antifreeze switch - Enable input
Antifreeze switch - Digital input confi gured
Antifreeze switch
Remote On/Off - Value reads from board
Remote On/Off - Enable input
Remote On/Off - Digital input confi gured
Remote On/Off
Supply fan overload 1 - Value reads from board
Supply fan overload 1 - Enable input
Supply fan overload 1 - Digital input confi gured
Supply fan overload 1
Return fan overload 1 - Value reads from board
Return fan overload 1 - Enable input
Return fan overload 1 - Digital input confi gured
Return fan overload 1
Supply fan overload 2 - Value reads from board
Supply fan overload 2 - Enable input
Supply fan overload 2 - Digital input confi gured
Supply fan overload 2
Return fan overload 2 - Value reads from board
Return fan overload 2 - Enable input
Return fan overload 2 - Digital input confi gured
Dim Modbus
1
DI1292
1
DI1293
1
DI1294
1
DI1295
1
DI1296
1
DI1297
1
DI130
DI1304
1
DI1305
1
DI1306
1
DI1307
1
DI1308
1
DI1309
1
DI131
1
DI132
1
DI133
1
DI134
1
DI135
1
DI136
1
DI137
1
DI138
1
DI139
1
DI140
1
DI141
1
DI142
1
DI143
1
DI144
1
DI145
1
DI146
1
DI147
1
DI148
1
DI149
1
DI150
1
DI151
1
DI152
1
DI153
1
DI154
1
DI155
1
DI156
1
DI157
1
DI158
1
DI159
1
DI160
1
DI161
1
DI162
1
DI163
1
DI164
1
DI165
1
DI166
1
DI167
1
DI168
1
DI169
1
DI170
1
DI171
1
DI172
1
DI173
1
DI174
1
DI175
1
DI176
1
DI177
Tableau des variables de supervision
FRE
BACnet
BV1518
BV1519
BV1520
BV1521
BV1522
BV1523
BV588
BV3941
BV3942
BV3943
BV3944
BV3945
BV3946
BV589
BV590
BV591
BV592
BV593
BV594
BV595
BV596
BV597
BV598
BV599
BV600
BV601
BV602
BV603
BV604
BV605
BV606
BV607
BV608
BV609
BV610
BV611
BV612
BV613
BV614
BV615
BV616
BV617
BV618
BV619
BV620
BV621
BV622
BV623
BV624
BV625
BV626
BV627
BV628
BV629
BV630
BV631
BV632
BV633
BV634
BV635
147