5 .3 Installing the Relilight V 61 .5 I2
Proceed as follows:
1 Strip the cable as shown in the figure and align the
cores.
8 mm
30 mm
Stripping the cable.
2 Break out the spacers from the top and bottom shell.
Breaking out the spacers.
3 Depending on the cable diameter, insert the adapters in
the cable joint.
Inserting the adapters.
6,5 - 12,0 mm
6 x 0,5 - 6 x 1,5 mm²
f Select the adapters for the corresponding cable
diameters.
< Ø9,5 mm
> Ø9,5 mm
Selecting the adapters.
4 Connect the cores with the connector.
Connecting the cores.
5 Insert the cable connection into the bottom shell.
Inserting the cable connection.