Télécharger Imprimer la page

Reflex omat RSC Smart AT8300A Mode D'emploi Original page 31

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Register
Register
Description
Address
Address
(dec)
(hex)
26
0x1A
Operating
hours (High-
Word)
27
0x1B
Operating
hours (Low-
Word)
30
0x1E
Water meter
(High-Word)
31
0x1F
Water meter
(Low-Word)
33
0x21
System type
36
0x24
Operating
mode
36
0x24
Operating
mode
36
0x24
Operating
mode
38
0x26
Conductivity
11
Maintenance
CAUTION
Risk of burns
Escaping hot medium can cause burns.
Maintain a sufficient distance from the escaping medium.
Wear suitable personal protective equipment (safety gloves and
goggles).
DANGER
Risk of serious injury or death due to electric shock.
If live parts are touched, there is risk of life-threatening injuries.
Ensure that the supply cable to the device is disconnected and secured
against being switched back on.
Ensure that the system is secured and cannot be reactivated by other
persons.
Ensure that installation work for the electric connection of the device is
carried out by an electrician, and in compliance with electrical locally
applicable electrical engineering regulations.
The device must be maintained annually.
The maintenance intervals depend on the local operational conditions.
An indication that the annual service is to be performed after the set device
operating time has elapsed is given in the form of a warning. The warning is also
displayed in the app. The maintenance interval must be reset using the app.
Use operating mode "manual mode" for maintenance  8.1.3 "Manual mode",
 27.
Injuries can occur during maintenance work if the installation of the connections is
incorrect because pressurised condensate can suddenly escape. Ensure proper
connections for condensate draining.
Wear suitable personal protective equipment (safety glasses and safety gloves, for
example).
Regularly clean the vessel to remove condensate. The cleaning intervals depend
on the local operational conditions.

Note!
Maintenance tasks must only be carried out by specialist personnel or
Reflex Customer Service.
Bezeichnung
Unit
Bit Address
Betriebsstunden
h
-
(High-Word)
Betriebsstunden
h
-
(Low-Word)
Wasserzähler
l
-
(High-Word)
Wasserzähler (Low-
l
-
Word)
Anlagentyp
-
-
Betriebszustand
-
Bit 0 = 1
Betriebszustand
-
Bit 1 = 1
Betriebszustand
-
Bit 2 = 1
Leitfähigkeit
μS/cm
-
Reflexomat RSC Smart — 21.10.2025-Rev. C
Meaning
Compressor 1
Compressor 1
Accumulated sum Water
meter in litres
Accumulated sum Water
meter in litres
0x0: n.d.
=0x1: Variomat
=0x2: Variomat Giga
=0x3: Reflexomat
=0x4: Servitec Magcontrol
=0x5: Servitec
Levelcontrol
=0x6: Servitec_S
=0x7: Servitec_Mini
=0x8: Greenbox
=0x9: Fillcontrol
=0xB (Dec =11): Servimat
Manual
Stop
Auto
(Only for "Conductivity
monitoring" option)
11.1
Maintenance schedule
The maintenance schedule is a summary of maintenance tasks to be carried out
regularly.
Activity
Check for leak tightness.
Compressor.
Screw connections of the
compressed air connections.
Check switching points.
Cut-in pressure compressor.
Low water.
Make-up with water.
11.2
Checking switching points (during vessel draining)
Prerequisite for checking the switching points are the following correct settings:
Minimum operating pressure P
,  6.3.3 "Installation of the weight
0
measuring cell",  24.
Filling level measurement in the primary vessel.
Preparation
1.
Switch to Automatic mode.
2.
Close the cap valves upstream of the vessel.
3.
Record the indicated filling level (value in %) from the app.
4.
Drain the water from the vessel.

Note!
During vessel draining, continuously monitor the filling level and pressure
values in the app and check the switching points.
Check the cut-in pressure during draining
5.
Check the cut-in and cut-out pressure of the compressor.
(Factory setting)
The compressor cuts in at P
The compressor cuts out at P
Maintenance
Bedeutung
Kompressor 1
Kompressor 1
Aufgelaufene Summe in Litern
Aufgelaufene Summe in Litern
0x0: n.d.
=0x1: Variomat
=0x2: Variomat Giga
=0x3: Reflexomat
=0x4: Servitec Magcontrol
=0x5: Servitec Levelcontrol
=0x6: Servitec_S
=0x7: Servitec_Mini
=0x8: Greenbox
=0x9: Fillcontrol
=0xB (Dec =11): Servimat
Manuell
Stop
Auto
(nur bei Option
„Leitfähigkeitsüberwachung")
Interval
x
x
Annually
x
Annually
+ 0.3 bar.
0
+ 0.4 bar.
0
loading