Plunger disk does
not fit inside
cartridge
Cartridge holder
remains in the
down position
during mixing
cycle
Motor is not
running
10.
PROGRAM SELECTION
Up to 10 programs can be stored in the the TS6500 Mixer.
1.
Press the Set button (Fig. 4.0) to highlight the program number
selection.
2.
Press the (+) or (-) buttons to select the desired program.
3.
Press the Set button to exit.
11.
CYCLE COUNTER RESET
The cycle counter can record up to 99999 mix cycles. To reset the
cycle counter follow the below instructions:
1.
Press and hold Setup button for 3 seconds to enter setup mode.
2.
Once the setup mode is displayed, press and hold Setup button
again until the cycle counter resets to "00000".
25
• Wrong plunger disk
size
• Sensor and magnet
is not aligned
• No power to motor
• Motor burned out
• Use correct plunger
disk size
• Turn off unit and
adjust sensor /
magnet alignment
• Check motor
connection
• Replace motor